39
PN: 81127
Rev 4, 6/2017
values are not actually saved to file until you press the File Folder icon and save them as previously
defined.
Figure 30 - Example Timing and Instantaneous Test report
3.5
Advanced Pickup and Timing Test
Pressing the Circuit Breaker Curve Library test button icon will present a selection menu where the user
may select either Generic or a specific Manufacturer. Pickup and Timing tests are provided for a wide
variety of molded case and low voltage air frame circuit breakers. This includes time curves and time
curve algorithms for different specific breakers selectable by manufacturer, model number, frame size,
and curve
shape (inverse, moderately inverse, etc.). In addition it also includes ANSI and IEC standards
time curve algorithms located in the Manufacturer Specific pull-down menu.
3.5.1
Advanced Timing Test Setup
Press the Select Circuit Breaker Curve Library
button. The user will be presented with a menu
where the user can select the type of device to be tested either manufacturer specific or generic.