Me2, Fog Generator
Operating Guide, Rev: A/a
17 / 30
DMX
C
ONTROL
The MDG
Me2
can be controlled via a DMX512-A USITT standard protocol.
WARNING
Activating the
«DMX» mode («INTERFACE
MODE
DMX»)
, controls the MDG
Me2 only by DMX signal. If the DMX wire is
unplugged
or DMX
signal is lost
, the
generator
initiates an automatic shutdown procedure
.
Activating the
«AUTO» mode («INTERFACE
MODE
AUTO»)
, controls MDG
Me2 by DMX, only if there is a signal. If the DMX wire is
unplugged
or DMX
signal
is lost
, the generator
keeps the last DMX values
.
WARNING
In
«
AUTO Mode
»
, DMX commands always take precedence over Local commands.
The MDG
Me2
provides a simple way to check if there is DMX signal:
The user can change the DMX Start Address in the Interface Menu («
DMX Add
»), and choose any
value between 1 and 510 (512, last DMX channel).
The generator uses three (3) DMX channels:
Channel 1
0 (0%)
UNIT OFF
128 (50%)
UNIT ON
255 (100%)
Channel 2
0 (0%) – 255 (100%)
, FOG OUTPUT (from minimum to maximum)
Channel 3
0 (0%)
FOG OFF
128 (50%)
FOG ON
255 (100%)
These channels have the same behaviour that the menus of the local interface (see
Operating
instructions
paragraph).
No DMX Signal
DMX Signal
Summary of Contents for ME2
Page 2: ...Me2 Fog Generator Operating Guide Rev A a 2 30 Intentionally left blank...
Page 26: ...Me2 Fog Generator Operating Guide Rev A a 26 30 Dimensions...
Page 27: ...Me2 Fog Generator Operating Guide Rev A a 27 30...
Page 29: ...Me2 Fog Generator Operating Guide Rev A a 29 30 Declaration of conformity...
Page 30: ...Me2 Fog Generator Operating Guide Rev A a 30 30 Notes...