Me2, Fog Generator

 

 

Operating Guide, Rev: A/a 

14 / 30

 

O

PERATING INSTRUCTIONS

 

The 

MDG 

Me2 Fog Generator

 can be controlled either locally, with the keyboard, via DMX (

see 

DMX control and RDM Control

). This paragraph focuses on 

local control

Starting Procedures 
When powering up the generator, the control program configures the Input/Output, and loads 
the configuration parameters saved in the EEPROM memory. 

At this point, the 

MDG 

Me2

 switches to stand-by mode, and most of the electronic controls are 

off. 

When the generator is manually switched to 

«UNIT ON»

 mode («CONTROL

UNIT

ON»), the 

program starts the heating cycle («STATUS

STATE = % HEAT»), which will last approximately 7 

to 8 minutes.   
When  the  temperature  reaches  READY  level  («STATUS

STATE  =  READY»),  the  Automatic 

Purging System™ (APS™) will be initiated («STATUS

STATE = PURGING»).   

After the first purging cycle is completed (approx. time 30 sec.) the generator is ready to produce 
fog.  

Fog Production 
When  the  generator  is  manually  switched  to 

«FOG  ON»

  mode  («CONTROL

FOG

ON»),  the 

Me2

 will start producing fog. 

The  amount  of  the  fog  emission  can  be  controlled  by  adjusting  the  pressure 
(«CONTROL

PRESSURE

XX») from 5 psi to 40 psi. 

The MDG 

Me2

 will produce fog as long as the control parameters are within specifications, and 

the fog fluid reservoir filled.  
If  a  critical  problem  occurs,  the  program  shuts  down  automatically  the  fog  generator,  and 
displays an error message in the 

State Menu

 (see 

Fail State

) and the LCD will flash. 

When the generator is manually switched to 

«FOG OFF»

 mode («CONTROL

FOG

OFF»), the 

Me2

 will stop producing haze and initiate the automatic purging cycle. 

 

 

WARNING

  

Never  power  off  a  generator  while  it  is  producing  fog 

  See  the  shut  down 

procedure.

 

 
 

 

Summary of Contents for ME2

Page 1: ...A D E IN CAN A D A F A B R IQU AU CA N A D A 10301 avenue Pelletier Montr al Qu bec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com Operating Guide...

Page 2: ...Me2 Fog Generator Operating Guide Rev A a 2 30 Intentionally left blank...

Page 3: ...ight Notice 5 Basic description 6 Installing the Me2 8 Working with the Me2 9 The Keyboard 10 LCD Saver 10 Menu Tree 11 Operating instructions 14 DMX Control 17 Bootloader 18 RDM Control 18 Fog fluid...

Page 4: ...nufacturer its service agent or similarly qualified persons in order to avoid a hazard HOW TO READ THIS OPERATING GUIDE WARNING and CAUTION are used throughout this manual to forewarn of possible dang...

Page 5: ...installation We re looking forward to go that extra mile for you Contact us By Phone 1 800 663 3020 1 514 272 6040 By Fax 1 514 722 3229 By e mail info mdgfog com On the Web www mdgfog com The QR code...

Page 6: ...g until the temperature of the heating module is back within parameters A fourth safety system consists of a pressure relief valve which limits the working pressure and protects against over pressure...

Page 7: ...erator Operating Guide Rev A a 7 30 MAIN POWER Switch VAC Input 100 250 VAC 50 60 Hz Handle Fog output nozzles XLR 5 DMX RDM Connector LCD Keyboard Fog fluid reservoir CO2 or N2 Gas input 50 60 psi US...

Page 8: ...quires 2 m 6 56 ft of clearance to the front Fill the reservoir with MDG Neutral Fog Fluid see Filling the Fluid Reservoir paragraph Connect the gas inlet to a gas bottle equipped with a single or dou...

Page 9: ...Load These four seconds allow you to connect the generator to your PC via a USB cable to update the firmware of the control board see BootLoader for further details Then the MDG Me2 will display durin...

Page 10: ...e reaches its maximum value the program continues with the minimum value Mode moves the last selection to the upper level This key has no effect in the first level In a data input menu pressing this k...

Page 11: ...to define or verify the communication via DMX RDM Settings Menu summarizes general configuration of the generator The menu is refreshed every second Items preceded by the character are state messages...

Page 12: ...is off due to a failure see diagnostic ERROR Error message when State FAIL see diagnostic TEMP Temperature status heating module TOO LOW temperature too low OK temperature within specifications ready...

Page 13: ...R yyy DMX Address 1 to 510 Network DMX RDM 1 UNIT yyy Channel 1 value OFF 50 128 ON 2 OUTPUT yyy Channel 2 value 0 0 to 100 255 3 FOG yyy Channel 3 value OFF 50 128 ON SETTINGS Settings menu UNITS Uni...

Page 14: ...omatic Purging System APS will be initiated STATUS STATE PURGING After the first purging cycle is completed approx time 30 sec the generator is ready to produce fog Fog Production When the generator i...

Page 15: ...mperature of the heating module is not increasing with the proper thermal ramp This is generally due to a heater cartridge s problem Shut down the generator and restart it Check the heating process wi...

Page 16: ...or a sensor problem Shut down the generator and restart it ERROR PCB HIGH LAST ERR CODE D This error will occur when the internal temperature of the generator is too high This may happen if the extern...

Page 17: ...signal is lost the generator keeps the last DMX values WARNING In AUTO Mode DMX commands always take precedence over Local commands The MDG Me2 provides a simple way to check if there is DMX signal T...

Page 18: ...B Male Male type Contact the MDG Service to have the last package firmware upgrade for the MDG Me2 RDM CONTROL The MDG Me2 can be controlled via a RDM ANSI E1 20 protocol an intelligent bi directional...

Page 19: ...FO 0x0060 PRODUCT_DETAIL_ID_LIST 0x0070 DEVICE_MODEL_DESCRIPTION 0x0080 White Mineral oil hazer MANUFACTURER_LABEL 0x0081 MDG Fog Generators Ltd DEVICE_LABEL 0x0082 SOFTWARE_VERSION_LABEL 0x00C0 DMX_P...

Page 20: ...G distributors or dealers Available in 4 L 1 US gallon 5 L Europe Only 20 L 5 3 US gallon 205 L 55 US gallon and 1000 L 264 US gallon FILLING THE FLUID RESERVOIR WARNING Use only MDG Neutral Fog Fluid...

Page 21: ...1415 W Verify the AC voltage on the power cord 100 250 VAC The generator does not produce fog Verify that the Unit is ON CONTROL UNIT ON Verify that the UNIT is READY STATUS STATE READY The generator...

Page 22: ...alfunction Restart the generator Please contact MDG Service if this problem persists ERROR HEATER This is a heating timeout due to a cartridge heater problem Restart the generator and check the heatin...

Page 23: ...SET Restart the generator Please contact MDG Service if this problem persists LCD displays strange letters or does not seem to work normally In some conditions Radio transmission or static discharges...

Page 24: ...easier on your generator with special compartments for accessories like cable extensions and remote control timers PORTABILITY OPTION The portability option stores the gas canister securely underneath...

Page 25: ...kg 5 9 lb per hour at 2 76 bar 40 psi Automatic Purging System Standard feature Warm up time 8 minutes Operating voltage 100 250 VAC 50 60Hz 1 phase Ground Earth connection REQUIRED Power consumption...

Page 26: ...Me2 Fog Generator Operating Guide Rev A a 26 30 Dimensions...

Page 27: ...Me2 Fog Generator Operating Guide Rev A a 27 30...

Page 28: ...his warranty MDG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines respo...

Page 29: ...Me2 Fog Generator Operating Guide Rev A a 29 30 Declaration of conformity...

Page 30: ...Me2 Fog Generator Operating Guide Rev A a 30 30 Notes...

Reviews: