Me2, Fog Generator
Operating Guide, Rev: A/a
14 / 30
O
PERATING INSTRUCTIONS
The
MDG
Me2 Fog Generator
can be controlled either locally, with the keyboard, via DMX (
see
DMX control and RDM Control
). This paragraph focuses on
local control
.
Starting Procedures
When powering up the generator, the control program configures the Input/Output, and loads
the configuration parameters saved in the EEPROM memory.
At this point, the
MDG
Me2
switches to stand-by mode, and most of the electronic controls are
off.
When the generator is manually switched to
«UNIT ON»
mode («CONTROL
UNIT
ON»), the
program starts the heating cycle («STATUS
STATE = % HEAT»), which will last approximately 7
to 8 minutes.
When the temperature reaches READY level («STATUS
STATE = READY»), the Automatic
Purging System™ (APS™) will be initiated («STATUS
STATE = PURGING»).
After the first purging cycle is completed (approx. time 30 sec.) the generator is ready to produce
fog.
Fog Production
When the generator is manually switched to
«FOG ON»
mode («CONTROL
FOG
ON»), the
Me2
will start producing fog.
The amount of the fog emission can be controlled by adjusting the pressure
(«CONTROL
PRESSURE
XX») from 5 psi to 40 psi.
The MDG
Me2
will produce fog as long as the control parameters are within specifications, and
the fog fluid reservoir filled.
If a critical problem occurs, the program shuts down automatically the fog generator, and
displays an error message in the
State Menu
(see
Fail State
) and the LCD will flash.
When the generator is manually switched to
«FOG OFF»
mode («CONTROL
FOG
OFF»), the
Me2
will stop producing haze and initiate the automatic purging cycle.
WARNING
Never power off a generator while it is producing fog
–
See the shut down
procedure.
Summary of Contents for ME2
Page 2: ...Me2 Fog Generator Operating Guide Rev A a 2 30 Intentionally left blank...
Page 26: ...Me2 Fog Generator Operating Guide Rev A a 26 30 Dimensions...
Page 27: ...Me2 Fog Generator Operating Guide Rev A a 27 30...
Page 29: ...Me2 Fog Generator Operating Guide Rev A a 29 30 Declaration of conformity...
Page 30: ...Me2 Fog Generator Operating Guide Rev A a 30 30 Notes...