Me2, Fog Generator
Operating Guide, Rev: A/a
12 / 30
The tree menu architecture is explained below. Items highlighted in blue are state menu ( - ), and
those highlighted in yellow are control menu (
).
STATUS
Status menu
STATE
----
Status
State
UNIT OFF
- the generator is
off
xx% HEAT
- the generator is
heating
, but not ready
PURGE
- the generator is
purging
the heating module
READY
- the generator is generator is
ready
to produce fog
FOG ON
- the generator is producing
Fog
FAIL
- the generator is off, due to a
failure
(see diagnostic)
ERROR
----
Error
message when
State = FAIL
(see diagnostic)
TEMP.
----
Temperature
status (heating module)
TOO LOW
- temperature
too low
OK
- temperature within specifications (
ready
)
TOO HIGH
- temperature
too high
PRESSURE
xx.x
Current reservoir
pressure
PCB TEMP
----
Temperature
of the board (see Units)
RUN TIME
xx.x
Total Run Time in decimal hours
FOG TIME
xx.x
Total Fog Time in decimal hours
LAST ERR
yyyyy
Code for the Last five (5) errors
See
Fail State
paragraph
CONTROL
Control menu
UNIT
----
Unit
toggle
OFF
- the generator is
off
ON
- the generator is
on
FOG
----
Fog
toggle
OFF
- the fog is
off
ON
- the fog is
on
SET PRES.
xx.x
Fog
operating
pressure
(see Units)
Summary of Contents for ME2
Page 2: ...Me2 Fog Generator Operating Guide Rev A a 2 30 Intentionally left blank...
Page 26: ...Me2 Fog Generator Operating Guide Rev A a 26 30 Dimensions...
Page 27: ...Me2 Fog Generator Operating Guide Rev A a 27 30...
Page 29: ...Me2 Fog Generator Operating Guide Rev A a 29 30 Declaration of conformity...
Page 30: ...Me2 Fog Generator Operating Guide Rev A a 30 30 Notes...