Me2, Fog Generator
Operating Guide, Rev: A/a
6 / 30
Basic description
The
Me2 Fog Generator
was designed with safety and reliability in mind. It is capable of
generating pure white, non-toxic fog for as long as you have fluid (100% duty cycle). This
generator is also equipped, as a standard feature, with the
Automatic Purging System
™
(
APS
™). This system purges the heating module after the first heating cycle and after every
emission of fog preventing residual build up and clogging.
The
Me2
is a variable output Fog Generator capable of generating large volumes of very dense
fog in a short period of time. It is one of the quietest units on the market.
At the heart of the
MDG Me2
is an electronic assembly that keeps the heat exchanger at a very
stable temperature, with three different types of fail-safe systems. Those three types of electronic
fail-safe systems are designed to protect against over and under-heating conditions and against
component failure. When an overheating condition is detected, or if the internal temperature of
the generator reaches 60°C (140°F), a safety circuit is triggered. This circuit removes the power
to the heating elements, preventing hazardous conditions. When an under-heating condition
occurs, the generator will stop producing fog until the temperature of the heating module is
back within parameters.
A fourth safety system consists of a pressure relief valve which limits the working pressure and
protects against over-pressure.
The temperature of the heat exchanger is maintained within a narrow margin. If an error occurs
(see
FAIL State
), the Fog Generator will automatically shut down. When one of the safety
systems is activated, the Fail state will be displayed on the LCD, in the Status Menu. Check the
FAIL State
and
Troubleshooting
paragraphs for diagnostics, then shut down the main power
switch, wait 30 seconds, and then switch the generator back on. If the failure persists, send your
generator back to an authorized service center for verification.
When « Fog On » mode is activated (DMX or Control Menu), the MDG
Me2 Generator
will
produce fog for as long as the ready level is reached (temperature) and all other control
parameters are within specifications.
When « Fog On » mode is deactivated, the
APS™
cycle is automatically initiated to clear the
heating module. Never remove the power to a generator while it is producing fog – See the
Shut
down procedure
.
WARNING
When not in use
ALWAYS
switch off the power switch located on the back
panel, and
disconnect both gas and AC line.
Never install above people
.
This
Me2
Fog Generator
must be installed in an upright position on a stable and
leveled surface.
Use in a well-ventilated area.
Do not operate at less than 2 meters (6.5 ft.) from people.
Summary of Contents for ME2
Page 2: ...Me2 Fog Generator Operating Guide Rev A a 2 30 Intentionally left blank...
Page 26: ...Me2 Fog Generator Operating Guide Rev A a 26 30 Dimensions...
Page 27: ...Me2 Fog Generator Operating Guide Rev A a 27 30...
Page 29: ...Me2 Fog Generator Operating Guide Rev A a 29 30 Declaration of conformity...
Page 30: ...Me2 Fog Generator Operating Guide Rev A a 30 30 Notes...