41
6-HYDRAULIC CONNECTION
Technical Dept. - All rights reserved - Reproduction is prohibited
SETTINGS TO BE CARRIED OUT BEFORE THE INITIAL START-UP
ON/OFF
When the power supply cable is connected to the bottom of the product, place the switch, which is on the pellet loading hatch, in position
(I). The luminous switch button will light up.
The product stays off and an initial screen page appears on the panel with the word OFF. Press any key and MENU will appear on the screen.
The product is turned on and off by pressing
B
on the control panel for 2 seconds.
The start-up phase lasts approximately 15 minutes after which the product enters the steady state.
When the product is turned off by pressing
B
on the control panel, the cooling procedure starts, which means that fuel is no longer loaded,
the brazier is cleaned and ventilation runs until the product is cool enough.
FEED SCREW LOADING
This function can only be activated when the product is off and allows the pellets to be loaded into the loading system (feed screw). It
can be used each time the pellets finish in the hopper (see alarm A02). It is also useful to prevent failed start-ups (alarm A01) due to the
hopper being empty.
To activate the CARICA COCLEA (LOAD FEED SCREW) function, with the product switched off, on the control panel go to IMPOSTAZIONI
(SETTINGS), select CARICA COCLEA (LOAD FEED SCREW) and ON. When the pellets start descending into the brazier, deactivate the CARICA
COCLEA (LOAD FEED SCREW) system and turn the product on.
CONNECT THE SUPPLY
CABLE
I/O SWITCH