Start-up Procedure
The emergency stop on the steering column must not be pushed in.
Figure 65
Key Switch
The key switch on the steering column is used to initialize the MDC
controller and start the engine. The engine will not start until the MDC
has booted up and until intake manifold heater has properly warmed.
To start the MSV turn the key switch to the on position. Watch the
screen on the MDC. After an M-B splash screen the start up screen will
appear. Turn the key to start the engine.
Important:
Do not turn the key to engage the starter until the start up
screen is showing. If this happens the engine will not start. The key
must be returned to the off position and then moved back to start the
MDC software.
Trying to start the engine prior to the Startup screen appearing may
cause delays. Engine will not crank until manifold heater is at starting
temperature. Colder temps will cause delays.
1. The Engine Speeds are stored in the MDC memory.
2. Start the engine.
3. Use the MDC to determine if the correct attachments are
configured in the controls
4. With the engine idling, operate the attachments until the system
warms up.
5. Return to the main screen for operation.