48
BEFORE STORING A MACHINE THAT HAS A WATER-COOLED CONDENSER IN ENVIRON-
MENTS WITH TEMPERATURES BELOW 0°C, COMPLETELY EMPTY THE WATER FROM THE
MACHINE COOLING SYSTEM, AS IT COULD FREEZE INSIDE IT, CAUSING VERY SERIOUS
DAMAGE.
DO NOT USE LIQUIDS BECAUSE THEY WOULD FIX THE DUST ON THE CONDENSER.
REMOVE DUST FROM THE CONDENSER GRILLES OUTWARDS TO AVOID COMPROMISING
THE PERFORMANCE OF THE REFRIGERATING SYSTEM.
9 INACTIVITY
9.1 Keeping the machine efficient if it remains inactive
If the machine will not be used for a lengthy period, follow these instructions:
-
Sanitise the machine as described in sec. 6.1.
-
Switch off the machine using the I/O - ON/OFF button, power down at the mains master switch and take the
plug out of the socket.
If the machine that will be inactive has a water-cooled condenser, close the Water In tap and discharge the water
pressure in the delivery tube by unscrewing the end connector. Remove both the delivery tube and the drainage tube
and empty the water from them. Before using again after a long period of inactivity, check the connector gaskets for
damage, substituting them if necessary.
If a machine with an air-cooled condenser has been inactive, before switching it on remove dust from the condenser
grilles “dry” with a vacuum cleaner and, if necessary, a brush, so that the dust is removed outwards.
Contact the Technical assis-
tance service.
NO
Turn the machine off and wait for about
20 minutes before restarting it (so the
rotary pressure pump motor safety tem-
perature is reset).
YES
The rotary pressure pump motor
is overheating due to overuse.
Cream has been continually dis-
pensed for too long (more than 5
minutes).
DISPENSING DOES NOT START OR IS SUDDENLY BLOCKED WITHOUT TRIPPING THE
EXTERNAL ELECTRIC SAFETY DEVICES
Summary of Contents for 2 Levels
Page 1: ...Operating Maintenance Manual Maxima Cream Whipping Machines ...
Page 2: ...2 ...
Page 6: ......
Page 15: ...Chapter 2 Technical Specifications 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ...