40
DO NOT PUT GASKETS IN THE INDUSTRIAL DISHWASHER, AS THE HIGH TEMPERATURES
COULD DEFORM THEM, MAKING THEM UNUSABLE.
Air regulator gaskets:
FOR CORRECT GASKET CLEANING, USE A DISPOSABLE CLOTH AND A
DETERGENT FOR ITEMS AND MACHINES USED FOR FOOD PREPARATION.
7.4 Maintenance sheets
Replacing the gaskets
S01
CHECKING INTERVAL: 500 hours or quarterly
AUTHORISED OPERATOR: 1 Operator
TIME NEEDED: 5 minutes
TOOL: Non-metallic pointed tool
- Regularly check the integrity of the gaskets and substitute them if they are broken, worn or swollen.
- Only use original gaskets, made of food-safe rubber.
- A full spare set of all gaskets is supplied with the machine, plus a tube of food-safe grease for lubricating them.
•
Remove the air regulator from the pump cover and take out the worn
gaskets using a non-metallic pointed tool, taking care not to damage
the housing.
•
Eliminate any product residues from the housings and fit the new
gaskets, lubricating them with the food-safe grease supplied.
•
Refit the air regulator on the pump cover.
Valve holder and air adjustment valve gaskets:
•
Unscrew the air regulator knob by turning it in an anticlockwise di-
rection and slide out the valve holder and regulator valve vertically.
Remove the worn gaskets from the valve holder and valve using a
non-metallic pointed tool, taking care not to damage the housing.
•
Eliminate any product residues from the housings and fit the new gas-
kets, lubricating them with the food-safe grease supplied. Reposition
the valve holder and valve in the air regulator and screw on the knob.