COMMISSIONING OF D-MAX
2 - 1
SE-46C
Commissioning of the web guide controllers
www.maxcess.eu
MI 1071 1 A
2 COMMISSIONING OF D-MAX
D-MAX Web Guide
Controller
Note:
Detailed information about sensor calibration is available in the
"D-MAX Operating Instructions". "Supplementary Operating
Instructions“ may also be available.
Precondition:
The SE-46C sensor is connected to the D-MAX controller as
specified in the system diagram to X5 or X9.
The SE-46C must be operated from the OI-TS operator
interface, not from the OI-N operator interface of the D-MAX
system.
1. Calibrating the analog
signal inputs of the D-MAX
controller
Note:
Calibration for analog control signals must only be performed if
the SE-46C sensor is not connected via an Ethernet cable with
the D-MAX Controller.
1.1. Preparing the D-MAX
controller for the calibration
D-MAX OI-N operator interface:
∙
Press the A key to select the D-MAX controller to which the
SE-46C sensor is connected
∙
Press the F3 key to set "Manual" operating mode on the
selected D-MAX controller
∙
Press the F4 key to
- select the job with y = 'J' if the SE-46 sensor is connected to
input X5 or
- select the job with y = 'K' if the SE-46 sensor is connected
to input X9.
Figure 2.1: OI-TS Operating
Interface