COMMISSIONING OF FIFE-500
4 - 3
SE-46C
Commissioning of the web guide controllers
www.maxcess.eu
MI 1071 1 A
Inbetr
iebna
hme Fife-500.fm
OI-TS operator interface:
∙
Select signal assignment 10mA
FIFE-500 operator interface:
∙
Press the button to determine the second reference value
∙
Press the YES button to save the calibration
1.4. Calibrating the locking
signal on the FIFE-500
FIFE-500 operator interface:
∙
Press the SENSOR button until sensor material or printing
edge
§
(S1) is selected
∙
Press the START CALIBRATION button
OI-TS operator interface:
∙
Select signal assignment 0mA
FIFE-500 operator interface:
∙
Press the button to determine the first reference value