12.0
COMMUNICATION (OPTIONAL)
www.maxcessintl.com
MAGPOWR Spyder-Plus
MI 850A320 1 M
Page 55 of 60
Starting
Modbus
Register
Parameter Name
Parameter
Format
Parameter
Type
Used with
Control
Types
Read /
Write
Range
0x44
System Type (Load Cell)
BYTE
Data
LC
Read /
Write
0 = Unwind
1 = Rewind
2 = Type 1
3 = Type 2
4 = Type 3
5 = Type 4
0x45
System Type (Dancer)
BYTE
Data
DT, DS
Read /
Write
0 = Unwind
1 = Rewind
0x46
Control Type
BYTE
Data
LC, DT, DS,
OPT
Read /
Write
0 = Load Cell
1 = Dancer, Torque
2 = Dancer, Speed
3 = Tension, Diameter
0x47
Output Range
BYTE
Data
LC, DT, DS
Read /
Write
0 = Normal
1 = -10V to +10V
0x48
Maximum Tension
FLOAT
Cal
LC, DT, DS
Read /
Write
{ 0.0 - 99999.0 } lb.
0x4A
Applied Tension
FLOAT
Cal
LC, DT, DS
Read /
Write
{ 0.0 - 99999.0 } lb.
0x4C
Core Diameter
FLOAT
Data
LC, OPT
Read /
Write
{ 0.0 - 999.0 } in.
0x4E
Full Roll Diameter
FLOAT
Data
LC, OPT
Read /
Write
{ 0.0 - 999.0 } in.
0x50
Diameter Calibration Constant
FLOAT
Cal
LC, OPT
Read /
Write
{ 0.0 - 99999.0 }
0x52
Tension Units
BYTE
Data
LC, DT, DS
Read /
Write
0 = pound
1 = ounce
2 = Kilogram
3 = Newton
4 = gram
0x53
Distance Units
BYTE
Data
LC, OPT
Read /
Write
0 = inch
1 = feet
2 = millimeter
3 = centimeter
4 = meter
0x54
Proportional Gain (Load Cell)
FLOAT
Data
LC
Read /
Write
{ 0.0 - 999.0 }
0x56
Integrator Time (Load Cell)
FLOAT
Data
LC
Read /
Write
{ 0.0 - 60.0 } seconds
0x58
Derivative Time (Dancer)
FLOAT
Data
DT
Read /
Write
{ 0.0 - 60.0 } seconds
0x5A
Error Limit
FLOAT
Data
LC, DT, DS
Read /
Write
{ 0.0 - 100.0 } %
0x5C
Start Time
FLOAT
Data
LC
Read /
Write
{ 0.0 - 60.0 } seconds
0x5E
Stop Time
FLOAT
Data
LC, DT, DS,
OPT
Read /
Write
{ 0.0 - 60.0 } seconds
0x60
Stop Multiplier
FLOAT
Data
LC, DT, OPT
Read /
Write
{ 0.0 - 99.0 }
0x62
Hold Level
FLOAT
Data
LC, DT
Read /
Write
{ 0.0 - 100.0 } %
0x64
Torque Output 0% Calibration Point
(0-10V, 4-20mA)
FLOAT
Cal
LC, DT, DS,
OPT
Read /
Write
{ 0.0 - 1.0 }
0x66
Torque Output 100% Calibration Point
(0-10V, 4-20mA)
FLOAT
Cal
LC, DT, DS,
OPT
Read /
Write
{ 0.0 - 1.0 }
0x68
Torque Output 0% Calibration Point
(-10V to +10V)
FLOAT
Cal
LC, DT, DS,
OPT
Read /
Write
{ 0.0 - 1.0 }
0x6A
Torque Output 100% Calibration Point
(-10V to +10V)
FLOAT
Cal
LC, DT, DS,
OPT
Read /
Write
{ 0.0 - 1.0 }
0x6C
Tension Meter 100% Calibration Point
FLOAT
Cal
LC, DT, DS,
OPT
Read /
Write
{ 0 - 511 }
0x6E
Tension Setpoint 0% Calibration Point
FLOAT
Cal
LC, OPT
Read /
Write
{ 0 - 4095 }