6.0 TENSION CONTROL
www.maxcessintl.com
MAGPOWR Spyder-Plus
MI 850A320 1 M
Page 14 of 60
6.2.2.1
CONTROL TYPE
Select the
“Load Cell” control type. Load cell systems must use a torque device; which can be a motor in torque
mode.
6.2.2.2
SYSTEM TYPE
Select the appropriate system type for the application, rewind, unwind, or one of the point to point types. See
Figure 6 for information on the point to point types.
6.2.2.3
OUTPUT RANGE
Select the main output range. For a main output range of either 0-10 VDC or 4-20 mADC select NORMAL. For the
–10 to +10 VDC range select “–10V to +10V”. The software is factory calibrated for the 0-10 VDC and the -10 to
+10 VDC output ranges. See Section 9.4 for recalibrating the output when using the 4-20 mADC range. See Figure
4 for jumper settings.
Figure 6 Load Cell System Types
6.2.2 CONFIGURE MENU
Navigate to the
Configure
menu. Press
. This section describes all
the screens in the Configure menu. This menu contains screens which
configure various options.