Separate tables are provided for:
10.1
General Problems
10.2
Tuning problems (Load Cell Control)
10.3
Tuning problems (Dancer Control)
10.4
Load cell calibration problems
10.5
Load Cell Diagnostic Voltages
10.1
General Problems
Problem
Possible Cause
Solution or Diagnostic
Screen blank or all dark.
Contrast grossly
misadjusted.
Remove power. Reapply power while holding
down the keys
and
. The Spyder will be
sweep through the contrast settings. When the
contrast is at or near the desired level, press
.
The Spyder will sweep through the contrast
settings repeatedly until
is pressed. The contrast
can be refined in the
Screen Contrast
screen.
See Section 13.1.
Power supply is low.
See Section 14.0, Specifications.
Screen difficult to read
Contrast misadjusted
Adjust contrast in the
Screen Contrast
screen.
This screen is the last screen in the
Configure
menu.
Output always high
E-Stop Active (unwinds)
For safety reasons E-Stop occurs with an open
circuit. The logic is therefore different than the
other digital inputs. E-Stop can also be mistakenly
activated by selecting Digital Input Mode Active
High when it is wired active low (and the other way
around). See Section 5.2 and Figure 4.
Process not running, but
Spyder is in AUTO mode
rather than in HOLD
mode.
When the process is not running the
tension/position control system is open loop. If the
tension/position is even slightly below Setpoint, the
Spyder will turn full ON attempting to correct the
tension/position.
Output always low
Tension ON/OFF set to
OFF
One or more of the external Tension On/Off
switches is active.
“Active” depends upon the Digital Input Mode. See
Section 5.2 and Figure 4.
E-Stop Active (All control
types except unwind)
For safety reasons E-Stop occurs with an open
circuit. The logic is therefore different than the
other digital inputs. E-Stop can also be mistakenly
activated by selecting Digital Input Mode Active
High when it is wired active low (and the other way
around). See Section 5.2 and Figure 4.
Process not running, but
Spyder is in Auto mode.
When the process is not running the
tension/position control system is open loop. If the
tension/position is even slightly above Setpoint, the
Spyder will turn full off attempting to correct the
tension/position.