CALIDO
Sanitary
water
heat
pump
16
9.2.1
Warnings
The
unit
must
be
securely
fixed
to
avoid
noise
and
shaking
:
when
insufficiently
installed,
the
unit
could
fall
causing
injury.
The
bearing
surface
should
be
flat
to
bear
the
weight
of
the
unit
and
suitable
for
installing
the
unit
without
increasing
noise
or
vibrations.
When
installing
the
unit
in
a
small
room,
please
take
measures
(like
sufficient
ventilation)
to
prevent
the
asphyxia
caused
by
the
leakage
of
refrigerant.
Be
sure
to
use
the
provided
or
specified
parts
for
the
installation
work:
the
use
of
defective
parts
could
cause
an
injury
due
to
possible
fire,
electric
shocks,
the
unit
falling
etc.
Do
not
tear
off
the
labels
on
the
unit:
the
labels
are
for
the
purpose
of
warning
or
reminding,
keeping
them
can
ensure
your
safe
operations.
Indoor
installation
is
compulsory:
it
is
not
allowed
to
install
the
unit
at
outdoor
or
rain
achieving
place
and
generally
accessible
from
any
source
of
water.
The
installation
place
without
direct
sunlight
and
other
heat
supplies
is
recommended:
if
no
way
to
avoid
these,
please
install
a
covering.
Make
sure
that
there’s
no
obstacles
around
the
unit.
9.2.2
Cautions
Do
not
install
the
unit
in
a
place
where
there
is
a
chance
of
flammable
gas
leaks
:
if
there
is
a
gas
leak
and
gas
accumulates
in
the
area
surrounding
the
unit,
it
could
cause
an
explosion.
Do
not
clean
the
unit
when
the
power
is
‘ON’:
always
shut
‘OFF’
the
power
when
cleaning
or
servicing
the
unit.
If
not,
it
could
cause
an
injury
due
to
the
high
speed
running
fan
or
an
electrical
shock.
Disconnect
the
appliance
from
the
power
supply
by
removing
the
plug
from
the
socket
or,
by
turning
off
the
main
switch
if
installed
upstream
of
the
unit.
Never
remove
the
plug
from
the
socket
by
pulling
out
the
power
cord.
Do
not
perform
cleaning
operations
of
the
machine
before
turning
off
the
unit,
unplugging
it
or
turning
off
the
external
switch.
In
case
the
unit
is
used
without
air
ejection
duct,
verify
that
the
installation
room
has
got
a
volume
not
less
than
10m
3
,
with
adequate
ventilation.
Please
note
that
the
temperature
of
the
expelled
air
is
5
‐
10°C
lower
than
the
inlet
air,
therefore
if
not
channelled
it
can
cause
a
significant
lowering
of
the
temperature
of
the
installation
room.
Do
not
continue
to
run
the
unit
when
there
is
something
wrong
or
there
is
a
strange
smell:
the
power
supply
needs
to
be
shut
‘OFF’
to
stop
the
unit;
otherwise
this
may
cause
an
electrical
shock
or
fire.
Inside
the
unit,
there
are
some
moving
parts.
Be
especially
careful
when
working
near
them,
even
if
the
unit
is
off.
Do
not
insert
fingers
or
other
objects
into
the
fan
and
evaporator.
The
temperatures
of
heads
and
exhaust
piping
of
the
compressor
are
usually
high.
Therefore
be
careful
when
working
near
condensing
coils.
The
aluminum
fins
are
very
sharp
and
can
cause
serious
injuries.
9.3
HANDLING
OF
THE
UNIT
As
a
rule,
the
unit
is
to
be
stored
and/or
handled
in
its
shipping
packing
box
in
upright
position
and
should
be
empty
without
water
charge.
During
the
transport
(provided
that
it
is
done
with
care)
and
the
storage,
it’s
advisable
to
not
exceed
an
inclination
angle
of
30
degrees
(45°
for
short
time).
Ambient
temperatures
for
storing
is
from
going
‐
20
to
+70
degrees
Celsius.
9.3.1
Handling
of
the
unit
with
forklift
When
using
the
forklift
for
handling,
the
unit
must
remain
mounted
on
the
pallet.
The
lifting
rate
should
be
kept
to
a
minimum.
Due
to
its
top
‐
heaviness,
the
unit
must
be
secured
against
tipping
over.
To
prevent
any
damage,
the
unit
must
be
placed
on
a
level
surface.
9.3.2
Manual
handling
of
the
unit
For
the
manual
handling,
the
wooden
pallet
can
be
used.
It’s
possible
to
use
ropes
or
carrying
straps,
taking
care
to
avoid
ioverturning
the
unit.
The
maximum
allowed
inclination
angle
is
45°,
the
vertical
position
is
advised.
If
transport
in
inclined
position
(with
maximum
angle
of
inclination
45°
for
shot
period
of
time)
cannot
be
avoided,
the
unit
should
be
taken
into
operation
one
hour
after
it
has
been
moved
into
final
position.