background image

CALIDO

 

Sanitary

 

water

 

heat

 

pump

 

35

18

 

FICHE

 

ACCORDING

 

TO

 

REGULATION

 

(EU)

 

No

 

812/2013

 

Modelli

 

/

 

Models

 

CALIDO

 

110

 

Profilo

 

di

 

carico

 

dichiarato

 

/

 

Declared

 

load

 

profile

 

M

 

Classe

 

di

 

efficienza

 

energetica

 

di

 

riscaldamento

 

dell’acqua

 

Water

 

heating

 

energy

 

efficiency

 

class

 

A

 

+

 

Efficienza

 

energetica

 

di

 

riscaldamento

 

dell’acqua

 

Water

 

heating

 

energy

 

efficiency

 

Aria

 

interna

 

+20°C

 

/

 

Indoor

 

air

 

+20°C

 

157%

 

Condizioni

 

climatiche

 

più

 

calde

 

(+14°C)

 

Warmer

 

climate

 

condition

 

138%

 

Condizioni

 

climatiche

 

medie

 

(+7°C)

 

Average

 

climate

 

conditions

 

125%

 

Condizioni

 

climatiche

 

più

 

fredde

 

(+2°C)

 

Colder

 

climate

 

conditions

 

113%

 

Consumo

 

annuo

 

di

 

energia

 

in

 

termini

 

di

 

energia

 

finale

 

Annual

 

energy

 

consumption

 

in

 

terms

 

of

 

final

 

energy

 

Aria

 

interna

 

+20°C

 

/

 

Indoor

 

air

 

+20°C

 

328

 

kWh

 

Condizioni

 

climatiche

 

più

 

calde

 

(+14°C)

 

Warmer

 

climate

 

condition

 

369

 

kWh

 

Condizioni

 

climatiche

 

medie

 

(+7°C)

 

Average

 

climate

 

conditions

 

410

 

kWh

 

Condizioni

 

climatiche

 

più

 

fredde

 

(+2°C)

 

Colder

 

climate

 

conditions

 

451

 

kWh

 

Impostazione

 

temperatura

 

termostato

 

Thermostat

 

temperature

 

settings

 

55°C

 

Livello

 

di

 

potenza

 

sonora

 

all’interno

 

L

WA

 

Sound

 

power

 

level,

 

indoor

 

L

WA

 

49

 

dB(A)

 

Precauzioni

 

di

 

installazione

 

e

 

manutenzione

 

Precautions

 

for

 

installation

 

and

 

maintenance

 

Per

 

le

 

indicazioni

 

relative

 

all’installazione

 

e

 

alla

 

manutenzione

 

riferirsi

 

ai

 

capitoli

 

dedicati

 

nel

 

manuale

 

utente

installatore.

 

Read

 

precautions

 

for

 

installation

 

and

 

maintenance

 

at

 

specific

 

chapters

 

on

 

user’s

 

and

 

installation’s

 

manual.

 

19

 

TECHNICAL

 

PARAMETERS

 

ACCORDING

 

TO

 

REGULATION

 

(EU)

 

No

 

814/2013

 

Modelli

 

/

 

Models

 

CALIDO

 

110

 

Consumo

 

quotidiano

 

di

 

energia

 

elettrica

 

Q

elec

 

Daily

 

electricity

 

consumption

 

Q

elec

 

Aria

 

interna

 

+20°C

 

/

 

Indoor

 

air

 

+20°C

 

1,553

 

kWh

 

Condizioni

 

climatiche

 

più

 

calde

 

(+14°C)

 

Warmer

 

climate

 

condition

 

1,749

 

kWh

 

Condizioni

 

climatiche

 

medie

 

(+7°C)

 

Average

 

climate

 

conditions

 

1,944

 

kWh

 

Condizioni

 

climatiche

 

più

 

fredde

 

(+2°C)

 

Colder

 

climate

 

conditions

 

2,138

 

kWh

 

Profilo

 

di

 

carico

 

dichiarato

 

/

 

Declared

 

load

 

profile

 

M

 

Livello

 

di

 

potenza

 

sonora

 

all’interno

 

/

 

Sound

 

power

 

level,

 

indoor

 

L

WA

 

49

 

dB(A)

 

Acqua

 

mista

 

a

 

40°C

 

V40

 

/

 

Mixed

 

water

 

at

 

40°C

 

V40

 

150

 

l

 

Efficienza

 

energetica

 

di

 

riscaldamento

 

dell’acqua

 

Water

 

heating

 

energy

 

efficiency

 

Aria

 

interna

 

+20°C

 

/

 

Indoor

 

air

 

+20°C

 

157%

 

Condizioni

 

climatiche

 

più

 

calde

 

(+14°C)

 

Warmer

 

climate

 

condition

 

138%

 

Condizioni

 

climatiche

 

medie

 

(+7°C)

 

Average

 

climate

 

conditions

 

125%

 

Condizioni

 

climatiche

 

più

 

fredde

 

(+2°C)

 

Ccolder

 

climate

 

conditions

 

113%

 

Summary of Contents for CALIDO 110

Page 1: ...ical specifications provided in this manual It is besides forbidden the reproduction under any form of the texts and of the figures contained in this manual This manual is a translation from the offic...

Page 2: ...Catalogue Katalog Catalogue MUI01110L8420 02 Serie Series Serie Serie S rie SANITARY WATER HEAT PUMP Possible wasted electrical or electronic devices products should not be located together with norm...

Page 3: ...EPIMENTO 2014 30 UE 2014 35 UE EVENTUALI ALTRE DIRETTIVE EUROPEE E NORME ARMONIZZATE APPLICATE ALL ATTREZZATURA EMC 2004 108 EC IEC 60335 2 21 IEC 60335 2 40 EN 55014 1 EN 61000 3 2 EN 61000 3 11 IS I...

Page 4: ...8 4 ACCESS TO THE BOTTOM PART 14 8 5 HOW TO REPLACE THE MAGNESIUM ANODE 14 8 6 REGULATION THERMOSTAT OF THE ELECTRIC HEATER 15 8 7 SCHEMATIC OVERVIEW OF THE WATER AND GAS CIRCUIT 15 9 INSTALLATION 15...

Page 5: ...5 5 Defrosting cycle 27 11 5 6 Anti freeze protection 27 11 6 PARAMETERS CONTROL AND SETTING 28 11 7 MALFUNCTIONING OF THE UNIT AND ERROR CODES 29 12 MAINTENANCE AND PERIODICAL CONTROLS 30 12 1 ENVIRO...

Page 6: ...or transcription The customer shall store any updated copy of the manual or parts of it delivered by the manufacturer as an attachment to this manual The company is available to give any detailed inf...

Page 7: ...d a number of directives on workplace s health and safety which include 89 391 CEE 89 686 CEE 2009 104 CE 86 188 CEE and 77 576 CEE directives Every employer shall implement such provisions and ensure...

Page 8: ...ymptoms may include loss of mobility and or consciousness Victims may not be aware of asphyxia Low concentration can have a narcotic effect The symptoms may include dizziness headache nausea and loss...

Page 9: ...nments a breathing apparatus or mask breathing air supply system must be used EN 137 Respiratory protective devices Self contained open circuit compressed air breathing apparatus with full face mask H...

Page 10: ...s it can contribute to the greenhouse effect It contains fluorinated greenhouse gases regulated by the Kyoto protocol DISPOSAL CONSIDERATIONS 13 1 Waste treatment methods Refer to the supplier gas rec...

Page 11: ...et makes the unit suitable for various ways of connections With different ways of installation the unit can work as just a heat pump but also as a fresh air blower a dehumidifier or an energy recovery...

Page 12: ...ple when you have the production of a photovoltaic system maximizing the self consumption and energy efficiency 7 ITEMS INSIDE THE PACKING BOX Before starting the installation please make sure that al...

Page 13: ...ole Hot water outlet Condensate drainage Cold water inlet G M Hot water outlet G M Condensate drainage 18mm 8 2 DIMENSIONS Air outlet Air inlet The lower part of the unit is white RAL9003 and the uppe...

Page 14: ...that hold the bottom central plate and remove the cover 1 Manual reset thermostat 2 Electric heater and magnesium anode 8 5 HOW TO REPLACE THE MAGNESIUM ANODE The Magnesium anode is an anti corrosion...

Page 15: ...he rules reported on this manual can create dangerous situations After receiving the unit immediately check its integrity The unit left the factory in perfect condition any eventual damage has to be q...

Page 16: ...In case the unit is used without air ejection duct verify that the installation room has got a volume not less than 10m3 with adequate ventilation Please note that the temperature of the expelled air...

Page 17: ...icity cables 2 Insert the supplied rawlplugs in the holes and fix the support bracket through the screws and washers 3 Secure the mounting bracket of the unit Make sure that is centered on the wall 4...

Page 18: ...e floor using the special anti vibration feet NOT supplied with the unit See the image below Vibration damper SUPPORTS for floor installation Vibration damper supports for floor installation If air in...

Page 19: ...to be operated regularly to remove lime deposits and to verify that it is not blocked Please beware of burn because of the high temperature of water The expansion tank with capacity suitably sized to...

Page 20: ...is clean after the unit has been installed and then check it periodically Perform the drainage piping work according to the installation instruction If there is a defect in the drainage piping work w...

Page 21: ...om water that may spatter In order to get access to the electrical box 1 remove the front part of the unit twist off the screws placed on the sides using a suitable long screwdriver it is possible to...

Page 22: ...o not modify the internal wiring of the unit otherwise the warranty will terminate immediately 11 APPLIANCE OPERATION 11 1 USER INTERFACE 11 2 OPERATION 1 Power ON When turning ON the power the whole...

Page 23: ...r off setting Press the and buttons to set the minutes and press to confirm the activation of the ON and then press the clock button to quit the timer setting mode The timer ON and timer OFF icons wil...

Page 24: ...equipped with the manual defrost control 5 Heating The icon indicates that the current operation mode of the system is heating by the heat pump 6 Heating and electric heater The presence of both icon...

Page 25: ...re when the water temperature of the tank becomes equal or higher than 85 C the electrical heater stops unless the protection is manually reset For the manual reset of the protection remove the bottom...

Page 26: ...er 4 The parameters 4 and 5 control the anti legionella cycle temperature versus time We recommend to respect the above guidelines if you want to change them Please remember that to keep the temperatu...

Page 27: ...h the maximum admissible temperature value given by the climatic curve and then the unit will operate according to the highest one of the comparison between both values P 20 1 the setting temperature...

Page 28: ...it 09 Maximum defrosting cycle time 1 12 min 8 min Only technician of TAC can change it 10 Operating mode of the electronic expansion valve 0 auto 1 manual 0 Only technician of TAC can change it 11 S...

Page 29: ...3 The electronic expansion valve assembly blocked 4 Too much refrigerant 5 The HP switch damaged 6 The uncompressed gas is in refrigerant system 1 Check if the air inlet temp is over the working limit...

Page 30: ...rect operation of the electric heater for the purpose of anti Legionella cycle Be sure to make a diagnosis with samples of water token from the critical points the whole hydraulic circuit x Check out...

Page 31: ...to proper collecting centre compressors lubricating oil has to be collected and sent to proper collecting centre the casing and various components if no longer serviceable must be dismantled and divi...

Page 32: ...o install externally Bar 8 Material of of the inner surface of the tank S235JR with double layer vitrification Auxiliary electric heater kW 1 5 Electronic expansion valve si Magnesium anode si Materia...

Page 33: ...tervention of the safety and protection devices In any case as regards high temperatures for water if the setting temperature is outside the operating region the unit will automatically adapt its set...

Page 34: ...CALIDO Sanitary water heat pump 34 17 WIRING DIAGRAM Please refer to the wiring diagram sticked on the electric box...

Page 35: ...door LWA 49 dB A Precauzioni di installazione e manutenzione Precautions for installation and maintenance Per le indicazioni relative all installazione e alla manutenzione riferirsi ai capitoli dedica...

Page 36: ......

Reviews: