CALIDO
Sanitary
water
heat
pump
29
11.7
MALFUNCTIONING
OF
THE
UNIT
AND
ERROR
CODES
When
an
error
occurs
or
the
protection
mode
is
set
automatically,
the
circuit
board
and
the
wired
controller
will
both
display
the
error
message.
Protection/
Malfunction
Error
code
LED
indicator
Possible
reasons
Corrective
actions
Standby
Dark
Normal
running
Bright
Lower
tank
water
temp.
sensor
failure
P01
☆
●
(1flash
1
dark)
1)
The
sensor
open
circuit
2)
The
sensor
short
circuit
1)
Check
the
sensor
connection
2)
Replace
the
sensor
Upper
tank
water
temp.
sensor
failure
P02
☆☆
●
(2
flashes
1
dark)
1)
The
sensor
open
circuit
2)
The
sensor
short
circuit
1)
Check
the
sensor
connection
2)
Replace
the
sensor
Evaporator
coil
temp.
sensor
failure
P03
☆☆☆
●
(3
flashes
1
dark)
1)
The
sensor
open
circuit
2)
The
sensor
short
circuit
1)
Check
the
sensor
connection
2)
Replace
the
sensor
Return
gas
temp
sensor
failure
P04
☆☆☆☆
●
(4
flashes
1
dark)
1)
The
sensor
open
circuit
2)
The
sensor
short
circuit
1)
Check
the
sensor
connection
2)
Replace
the
sensor
Ambient
temp.
sensor
failure
P05
☆☆☆☆☆
●
(5
flashes
1
dark)
1)
The
sensor
open
circuit
2)
The
sensor
short
circuit
1)
Check
the
sensor
connection
2)
Replace
the
sensor
Antifreez
protection
failure
P06
☆☆☆☆☆☆☆☆☆☆
●
(10
flashes
1
dark)
High
pressure
protection
(HP
Switch)
E01
☆☆☆☆☆☆
●
(6
flashes
1
dark)
1)
Too
high
air
inlet
temp
2)
Less
water
in
the
tank
3)
The
electronic
expansion
valve
assembly
blocked
4)
Too
much
refrigerant
5)
The
HP
switch
damaged
6)
The
uncompressed
gas
is
in
refrigerant
system
1)
Check
if
the
air
inlet
temp
is
over
the
working
limit
2)
Check
if
the
tank
is
full
of
water.
If
not,
charge
water
3)
Replace
the
electronic
expansion
valve
assembly
4)
Discharge
some
refrigerant
5)
Replace
a
new
switch
6)
Discharge
and
then
recharge
the
refrigerant
Low
pressure
protection
(LP
Switch)
E02
☆☆☆☆☆☆☆
●
(7
flashes
1
dark)
1)
Too
low
air
inlet
temp
2)
The
electronic
expansion
valve
assembly
blocked
3)
Too
less
refrigerant
4)
The
LP
switch
damaged
5)
The
fan
assembly
can
not
work
1)
Check
if
the
air
inlet
temp
is
over
the
working
limit
2)
Replace
the
electronic
expansion
valve
assembly
3)
Charge
some
refrigerant
4)
Replace
a
new
switch
5)
Check
if
the
fan
working
when
the
compressor
working.
If
not,
some
problems
with
the
fan
assembly
High
temperature
protection
(Automatic
thermostat
T80°C
Switch)
E03
☆☆☆☆☆☆☆☆
●
(8
flashes
1
dark)
1)
Too
high
tank
water
temp
2)
The
T85°C
switch
damaged
1)
If
the
tank
water
temp
is
over
80°C,
the
switch
will
open
and
the
e
‐
heater
will
stop
for
protection.
When
water
temperatures
becomes
normal,
the
protection
is
auto
‐
reset
2)
Replace
a
new
switch
Compressor
protection
PA
☆☆☆☆☆☆☆☆☆
●
(9
flashes
1
dark)
The
compressori
s
operating
out
of
the
air
and/or
water
temperature
limits
Wait
for
the
air
temperature
to
become
normal
for
operation.
Defrosting
☆☆☆☆☆☆☆☆
(Flashes
in
a
continuous
fashion)
Wait
the
termination
of
the
defrosting
cycle
Communication
failure
E08
Bright