CALIDO
Sanitary
water
heat
pump
27
11.5.4
Contact
for
photovoltaic
plant
integration
The
ON/OFF
contact
can
be
configured
so
that
a
photovoltaic
plant,
in
max
production
periods,
can
be
used
to
obtain
the
max
value
of
hot
water
by
the
unit
(set
the
parameter
17
to
be
1).
When
the
contact
is
closed
(activation
by
FV
plant),
the
tank
setting
temperature
TS1
is
increased
to
the
max
possible
value,
according
to
the
settings
of
the
parameter
P.20.
-
P.20
=
0
(default),
the
temperature
value
introduced
manually
is
compared
with
the
maximum
admissible
temperature
value
given
by
the
climatic
curve,
and
then
the
unit
will
operate
according
to
the
highest
one
of
the
comparison
between
both
values.
-
P.20
=
1,
the
setting
temperature
will
be
equal
to
(65°C).
11.5.5
Defrosting
cycle
Especially
when
the
unit
works
when
the
outside
temperature
is
very
low,
frost
may
appear
on
the
evaporator.
In
this
case
the
defrost
process
is
activated
and
the
relative
LED
icon
flashes.
11.5.6
Anti
‐
freeze
protection
If
the
unit
is
switched
off
but
still
under
voltage,
and
the
tank
temperature
drops
below
5°C;
the
electric
heater
is
forced
to
work
until
reaching
the
same
temperature
at
10°C.
In
this
case
the
error
code
"
P06
"
will
appear
on
the
display
of
the
unit.
Summary of Contents for CALIDO 110