background image

CALIDO

 

Sanitary

 

water

 

heat

 

pump

 

11

5

 

GENERAL

 

CHARACTERISTICS

 

The

 

hot

 

water

 

heat

 

pump

 

is

 

one

 

of

 

the

 

most

 

economical

 

systems

 

to

 

heat

 

the

 

water

 

for

 

family

 

domestic

 

uses

 

or

 

for

 

small

 

business

 

activities.

 

Using

 

free

 

renewable

 

energy

 

from

 

the

 

air,

 

the

 

unit

 

is

 

highly

 

efficient

 

with

 

low

 

running

 

costs.

 

Its

 

efficiency

 

can

 

be

 

up

 

to

 

3~4

 

times

 

more

 

than

 

conventional

 

gas

 

boilers

 

or

 

electrical

 

heaters.

 

5.1

 

FLEXIBILITY

 

AND

 

BENEFITS

 

OF

 

CALIDO

 

INSTALLATION

 

Waste

 

heat

 

recovery:

 

the

 

unit

 

can

 

be

 

installed

 

near

 

the

 

kitchen,

 

in

 

the

 

boiler

room

 

or

 

the

 

garage,

 

basically

 

in

 

every

 

room

 

which

 

has

 

a

 

large

 

number

 

of

 

waste

heat

 

so

 

that

 

it

 

has

 

the

 

higher

 

energy

 

efficiency

 

even

 

with

 

very

 

low

 

outside

 

temperatures

 

during

 

the

 

winter.

 

 

Hot

 

water

 

and

 

dehumidification:

 

the

 

unit

 

can

 

be

 

placed

 

in

 

the

 

laundry

 

room

 

or

 

clothing

 

room.

 

When

 

it

 

produces

 

hot

 

water

 

it

 

lowers

 

the

 

temperature

 

and

 

dehumidifies

 

the

 

room

 

as

 

well.

 

 

Storage

 

room

 

cooling:

 

the

 

unit

 

can

 

be

 

placed

 

in

 

the

 

storage

 

room

 

as

 

the

 

low

 

temperature

 

helps

 

to

 

keep

 

the

 

food

 

fresh.

 

Hot

 

water

 

and

 

fresh

 

air

 

ventilation:

 

the

 

unit

 

can

 

be

 

placed

 

in

 

the

 

garage,

 

gym,

 

basement

 

etc.

 

When

 

it

 

produces

 

hot

 

water,

 

it

 

makes

 

cold

 

the

 

room

 

and

 

then

 

provides

 

fresh

 

air.

 

Ecological

 

and

 

economical

 

heating:

 

the

 

unit

 

is

 

one

 

of

 

the

 

most

 

efficient

 

and

 

economical

 

alternatives

 

to

 

both

 

fossil

 

fuel

 

boilers

 

and

 

heating

 

systems.

 

By

 

making

 

use

 

of

 

the

 

renewable

 

source

 

in

 

the

 

air,

 

it

 

consumes

 

much

 

less

 

energy.

 

Multiple

 

functions:

 

the

 

special

 

design

 

of

 

the

 

air

 

inlet

 

and

 

outlet

 

makes

 

the

 

unit

 

suitable

 

for

 

various

 

ways

 

of

 

connections.

 

With

 

different

 

ways

 

of

 

installation,

 

the

 

unit

 

can

 

work

 

as

 

just

 

a

 

heat

 

pump

 

but

 

also

 

as

 

a

 

fresh

 

air

 

blower,

 

a

 

dehumidifier,

 

or

 

an

 

energy

 

recovery

 

device.

 

 

The

 

function

 

for

 

which

 

the

 

unit

 

has

 

been

 

designed

 

is

 

only

 

that

 

of

 

heat

 

pump

 

for

 

DHW

 

production.

 

Any

 

other

 

side

 

effect

 

(ambient

 

cooling,

 

dehumidification,

 

waste

 

heat

 

recovery)

 

should

 

be

 

considered

 

as

 

a

 

perk,

 

on

 

which

 

you

 

can

 

not

 

have

 

however

 

precise

 

control.

 

The

 

performance

 

data

 

will

 

therefore

 

be

 

provided

 

only

 

with

 

respect

 

to

 

the

 

function

 

of

 

water

 

heating.

 

5.2

 

COMPACT

 

DESIGN

 

The

 

unit

 

is

 

designed

 

in

 

particular

 

for

 

supplying

 

hot

 

water

 

for

 

domestic

 

use

 

or

 

for

 

small

 

commercial

 

activities.

 

The

 

highly

 

compact

 

structure

 

and

 

elegant

 

design

 

of

 

the

 

appliance

 

are

 

studied

 

in

 

order

 

to

 

make

 

it

 

easy

 

and

 

simple

 

for

 

internal

 

installation.

 

5.3

 

AVAILABLE

 

ACCESSORIES

 

Available

 

accessories

 

are:

 

 

Vibration

 

damper

 

supports

 

for

 

floor

 

installation.

 

6

 

TECHNICAL

 

FEATURES

 

 

Steel

 

tank

 

with

 

double

 

layer

 

vitrification.

 

 

Anti

corrosion

 

magnesium

 

stick

 

for

 

assuring

 

the

 

durability

 

of

 

the

 

tank.

 

 

Condenser

 

wrapped

 

externally

 

to

 

the

 

boiler,

 

free

 

from

 

fouling

 

and

 

refrigerant

 

with

 

oil

water

 

contamination.

 

 

High

 

thickness

 

polyurethane

 

foam

 

(PU)

 

thermal

 

insulation.

 

 

External

 

structure

 

made

 

of

 

sheet

 

metal

 

in

 

two

 

colors:

 

the

 

lower

 

part

 

in

 

RAL

 

9003,

 

the

 

upper

 

part

 

in

 

RAL

 

7035.

 

 

Outer

 

shell

 

made

 

of

 

grey

 

colour

 

RAL

 

9006

 

plastic

 

material.

 

 

Highly

 

efficient

 

compressor

 

with

 

the

 

R134a

 

refrigerant.

 

 

High

 

and

 

low

 

gas

 

pressure

 

protections.

 

 

Electrical

 

heater

 

available

 

in

 

the

 

unit

 

as

 

a

 

back

up

 

(with

 

integrated

 

thermostat

 

with

 

protection

 

temp.

 

at

 

85°C+/

5°C),

 

assuring

 

constant

 

hot

 

water

 

even

 

in

 

extreme

 

cold

 

winters.

 

Summary of Contents for CALIDO 110

Page 1: ...ical specifications provided in this manual It is besides forbidden the reproduction under any form of the texts and of the figures contained in this manual This manual is a translation from the offic...

Page 2: ...Catalogue Katalog Catalogue MUI01110L8420 02 Serie Series Serie Serie S rie SANITARY WATER HEAT PUMP Possible wasted electrical or electronic devices products should not be located together with norm...

Page 3: ...EPIMENTO 2014 30 UE 2014 35 UE EVENTUALI ALTRE DIRETTIVE EUROPEE E NORME ARMONIZZATE APPLICATE ALL ATTREZZATURA EMC 2004 108 EC IEC 60335 2 21 IEC 60335 2 40 EN 55014 1 EN 61000 3 2 EN 61000 3 11 IS I...

Page 4: ...8 4 ACCESS TO THE BOTTOM PART 14 8 5 HOW TO REPLACE THE MAGNESIUM ANODE 14 8 6 REGULATION THERMOSTAT OF THE ELECTRIC HEATER 15 8 7 SCHEMATIC OVERVIEW OF THE WATER AND GAS CIRCUIT 15 9 INSTALLATION 15...

Page 5: ...5 5 Defrosting cycle 27 11 5 6 Anti freeze protection 27 11 6 PARAMETERS CONTROL AND SETTING 28 11 7 MALFUNCTIONING OF THE UNIT AND ERROR CODES 29 12 MAINTENANCE AND PERIODICAL CONTROLS 30 12 1 ENVIRO...

Page 6: ...or transcription The customer shall store any updated copy of the manual or parts of it delivered by the manufacturer as an attachment to this manual The company is available to give any detailed inf...

Page 7: ...d a number of directives on workplace s health and safety which include 89 391 CEE 89 686 CEE 2009 104 CE 86 188 CEE and 77 576 CEE directives Every employer shall implement such provisions and ensure...

Page 8: ...ymptoms may include loss of mobility and or consciousness Victims may not be aware of asphyxia Low concentration can have a narcotic effect The symptoms may include dizziness headache nausea and loss...

Page 9: ...nments a breathing apparatus or mask breathing air supply system must be used EN 137 Respiratory protective devices Self contained open circuit compressed air breathing apparatus with full face mask H...

Page 10: ...s it can contribute to the greenhouse effect It contains fluorinated greenhouse gases regulated by the Kyoto protocol DISPOSAL CONSIDERATIONS 13 1 Waste treatment methods Refer to the supplier gas rec...

Page 11: ...et makes the unit suitable for various ways of connections With different ways of installation the unit can work as just a heat pump but also as a fresh air blower a dehumidifier or an energy recovery...

Page 12: ...ple when you have the production of a photovoltaic system maximizing the self consumption and energy efficiency 7 ITEMS INSIDE THE PACKING BOX Before starting the installation please make sure that al...

Page 13: ...ole Hot water outlet Condensate drainage Cold water inlet G M Hot water outlet G M Condensate drainage 18mm 8 2 DIMENSIONS Air outlet Air inlet The lower part of the unit is white RAL9003 and the uppe...

Page 14: ...that hold the bottom central plate and remove the cover 1 Manual reset thermostat 2 Electric heater and magnesium anode 8 5 HOW TO REPLACE THE MAGNESIUM ANODE The Magnesium anode is an anti corrosion...

Page 15: ...he rules reported on this manual can create dangerous situations After receiving the unit immediately check its integrity The unit left the factory in perfect condition any eventual damage has to be q...

Page 16: ...In case the unit is used without air ejection duct verify that the installation room has got a volume not less than 10m3 with adequate ventilation Please note that the temperature of the expelled air...

Page 17: ...icity cables 2 Insert the supplied rawlplugs in the holes and fix the support bracket through the screws and washers 3 Secure the mounting bracket of the unit Make sure that is centered on the wall 4...

Page 18: ...e floor using the special anti vibration feet NOT supplied with the unit See the image below Vibration damper SUPPORTS for floor installation Vibration damper supports for floor installation If air in...

Page 19: ...to be operated regularly to remove lime deposits and to verify that it is not blocked Please beware of burn because of the high temperature of water The expansion tank with capacity suitably sized to...

Page 20: ...is clean after the unit has been installed and then check it periodically Perform the drainage piping work according to the installation instruction If there is a defect in the drainage piping work w...

Page 21: ...om water that may spatter In order to get access to the electrical box 1 remove the front part of the unit twist off the screws placed on the sides using a suitable long screwdriver it is possible to...

Page 22: ...o not modify the internal wiring of the unit otherwise the warranty will terminate immediately 11 APPLIANCE OPERATION 11 1 USER INTERFACE 11 2 OPERATION 1 Power ON When turning ON the power the whole...

Page 23: ...r off setting Press the and buttons to set the minutes and press to confirm the activation of the ON and then press the clock button to quit the timer setting mode The timer ON and timer OFF icons wil...

Page 24: ...equipped with the manual defrost control 5 Heating The icon indicates that the current operation mode of the system is heating by the heat pump 6 Heating and electric heater The presence of both icon...

Page 25: ...re when the water temperature of the tank becomes equal or higher than 85 C the electrical heater stops unless the protection is manually reset For the manual reset of the protection remove the bottom...

Page 26: ...er 4 The parameters 4 and 5 control the anti legionella cycle temperature versus time We recommend to respect the above guidelines if you want to change them Please remember that to keep the temperatu...

Page 27: ...h the maximum admissible temperature value given by the climatic curve and then the unit will operate according to the highest one of the comparison between both values P 20 1 the setting temperature...

Page 28: ...it 09 Maximum defrosting cycle time 1 12 min 8 min Only technician of TAC can change it 10 Operating mode of the electronic expansion valve 0 auto 1 manual 0 Only technician of TAC can change it 11 S...

Page 29: ...3 The electronic expansion valve assembly blocked 4 Too much refrigerant 5 The HP switch damaged 6 The uncompressed gas is in refrigerant system 1 Check if the air inlet temp is over the working limit...

Page 30: ...rect operation of the electric heater for the purpose of anti Legionella cycle Be sure to make a diagnosis with samples of water token from the critical points the whole hydraulic circuit x Check out...

Page 31: ...to proper collecting centre compressors lubricating oil has to be collected and sent to proper collecting centre the casing and various components if no longer serviceable must be dismantled and divi...

Page 32: ...o install externally Bar 8 Material of of the inner surface of the tank S235JR with double layer vitrification Auxiliary electric heater kW 1 5 Electronic expansion valve si Magnesium anode si Materia...

Page 33: ...tervention of the safety and protection devices In any case as regards high temperatures for water if the setting temperature is outside the operating region the unit will automatically adapt its set...

Page 34: ...CALIDO Sanitary water heat pump 34 17 WIRING DIAGRAM Please refer to the wiring diagram sticked on the electric box...

Page 35: ...door LWA 49 dB A Precauzioni di installazione e manutenzione Precautions for installation and maintenance Per le indicazioni relative all installazione e alla manutenzione riferirsi ai capitoli dedica...

Page 36: ......

Reviews: