background image

CALIDO

 

Sanitary

 

water

 

heat

 

pump

 

15

8.6

 

REGULATION

 

THERMOSTAT

 

OF

 

THE

 

ELECTRIC

 

HEATER

 

The

 

auxiliary

 

electric

 

heater

 

is

 

equipped

 

with

 

a

 

thermostat

 

for

 

regulation;

 

to

 

access

 

this

 

component,

 

you

 

should

 

remove

 

the

 

bottom

 

cover.

 

The

 

factory

 

setting

 

is

 

made

 

at

 

its

 

maximum

 

value

 

85°C;

 

any

 

modification

 

of

 

such

 

value

 

is

 

not

 

recommended

 

as

 

it

 

could

 

produce

 

malfunctions

 

on

 

the

 

legionella

 

cycle

 

control

 

(For

 

such

 

purpose

 

it

 

is

 

required

 

to

 

read

 

carefully

 

the

 

paragraph

 

11.5.2).

 

8.7

 

SCHEMATIC

 

OVERVIEW

 

OF

 

THE

 

WATER

 

AND

 

GAS

 

CIRCUIT

 

Low pressure switch

High pressure switch

Air inlet

Evaporator

Air outlet

Temp. sensor

Temp. sensor

Hot water outlet

Cold water inlet

Water tank

Compressor

4 way valve

Electronic expansion valve

 

9

 

INSTALLATION

 

 

WARNING:

 

All

 

the

 

operations

 

described

 

below

 

must

 

be

 

carried

 

out

 

only

 

by

 

QUALIFIED

 

PERSONNEL.

 

Prior

 

to

 

any

 

work

 

on

 

the

 

unit,

 

make

 

sure

 

that

 

the

 

power

 

supply

 

is

 

disconnected.

 

9.1

 

GENERALITY

 

When

 

installing

 

or

 

servicing

 

the

 

unit,

 

it

 

is

 

necessary

 

to

 

strictly

 

follow

 

the

 

rules

 

listed

 

in

 

this

 

manual,

 

to

 

conform

 

to

 

all

 

the

 

specifications

 

of

 

the

 

labels

 

sticked

 

on

 

the

 

unit,

 

and

 

to

 

take

 

any

 

possible

 

precautions.

 

Not

 

observing

 

the

 

rules

 

reported

 

on

 

this

 

manual

 

can

 

create

 

dangerous

 

situations.

 

 

After

 

receiving

 

the

 

unit,

 

immediately

 

check

 

its

 

integrity.

 

The

 

unit

 

left

 

the

 

factory

 

in

 

perfect

 

condition;

 

any

 

eventual

 

damage

 

has

 

to

 

be

 

questioned

 

to

 

the

 

carrier

 

and

 

recorded

 

on

 

the

 

Delivery

 

Note

 

before

 

signing

 

it.

 

The

 

company

 

has

 

to

 

be

 

informed,

 

within

 

8

 

days,

 

of

 

the

 

extent

 

of

 

the

 

damage.

 

The

 

Customer

 

should

 

prepare

 

a

 

written

 

statement

 

with

 

photographs

 

of

 

any

 

severe

 

damage.

 

 

Please

 

note

 

that

 

all

 

the

 

installation

 

diagrams

 

shown

 

in

 

this

 

chapter

 

are

 

only

 

a

 

guide.

 

The

 

correct

 

installation

 

plant

 

must

 

be

 

evaluated

 

case

 

by

 

case

 

by

 

the

 

installer.

 

9.2

 

SAFETY

 

INSTRUCTIONS

 

To

 

prevent

 

injury

 

to

 

the

 

user,

 

other

 

people,

 

or

 

property

 

damage,

 

the

 

following

 

instructions

 

must

 

be

 

followed.

 

Incorrect

 

operation

 

due

 

to

 

ignoring

 

of

 

instructions

 

may

 

cause

 

harm

 

or

 

damage.

 

Install

 

the

 

unit

 

only

 

when

 

it

 

complies

 

with

 

local

 

regulations,

 

by

laws

 

and

 

standards.

 

Check

 

the

 

main

 

voltage

 

and

 

frequency.

 

This

 

unit

 

is

 

only

 

suitable

 

for

 

earthed

 

sockets,

 

connection

 

voltage

 

220

 ‐ 

240

 

V

 

~

 

/

 

50Hz.

 

The

 

following

 

safety

 

precautions

 

should

 

always

 

be

 

taken

 

into

 

account:

 

-

 

be

 

sure

 

to

 

read

 

the

 

following

 

WARNING

 

before

 

installing

 

the

 

unit;

 

-

 

be

 

sure

 

to

 

observe

 

the

 

cautions

 

specified

 

here

 

as

 

they

 

include

 

important

 

items

 

related

 

to

 

safety;

 

-

 

after

 

reading

 

these

 

instructions,

 

be

 

sure

 

to

 

keep

 

it

 

in

 

a

 

handy

 

place

 

for

 

future

 

reference.

 

Summary of Contents for CALIDO 110

Page 1: ...ical specifications provided in this manual It is besides forbidden the reproduction under any form of the texts and of the figures contained in this manual This manual is a translation from the offic...

Page 2: ...Catalogue Katalog Catalogue MUI01110L8420 02 Serie Series Serie Serie S rie SANITARY WATER HEAT PUMP Possible wasted electrical or electronic devices products should not be located together with norm...

Page 3: ...EPIMENTO 2014 30 UE 2014 35 UE EVENTUALI ALTRE DIRETTIVE EUROPEE E NORME ARMONIZZATE APPLICATE ALL ATTREZZATURA EMC 2004 108 EC IEC 60335 2 21 IEC 60335 2 40 EN 55014 1 EN 61000 3 2 EN 61000 3 11 IS I...

Page 4: ...8 4 ACCESS TO THE BOTTOM PART 14 8 5 HOW TO REPLACE THE MAGNESIUM ANODE 14 8 6 REGULATION THERMOSTAT OF THE ELECTRIC HEATER 15 8 7 SCHEMATIC OVERVIEW OF THE WATER AND GAS CIRCUIT 15 9 INSTALLATION 15...

Page 5: ...5 5 Defrosting cycle 27 11 5 6 Anti freeze protection 27 11 6 PARAMETERS CONTROL AND SETTING 28 11 7 MALFUNCTIONING OF THE UNIT AND ERROR CODES 29 12 MAINTENANCE AND PERIODICAL CONTROLS 30 12 1 ENVIRO...

Page 6: ...or transcription The customer shall store any updated copy of the manual or parts of it delivered by the manufacturer as an attachment to this manual The company is available to give any detailed inf...

Page 7: ...d a number of directives on workplace s health and safety which include 89 391 CEE 89 686 CEE 2009 104 CE 86 188 CEE and 77 576 CEE directives Every employer shall implement such provisions and ensure...

Page 8: ...ymptoms may include loss of mobility and or consciousness Victims may not be aware of asphyxia Low concentration can have a narcotic effect The symptoms may include dizziness headache nausea and loss...

Page 9: ...nments a breathing apparatus or mask breathing air supply system must be used EN 137 Respiratory protective devices Self contained open circuit compressed air breathing apparatus with full face mask H...

Page 10: ...s it can contribute to the greenhouse effect It contains fluorinated greenhouse gases regulated by the Kyoto protocol DISPOSAL CONSIDERATIONS 13 1 Waste treatment methods Refer to the supplier gas rec...

Page 11: ...et makes the unit suitable for various ways of connections With different ways of installation the unit can work as just a heat pump but also as a fresh air blower a dehumidifier or an energy recovery...

Page 12: ...ple when you have the production of a photovoltaic system maximizing the self consumption and energy efficiency 7 ITEMS INSIDE THE PACKING BOX Before starting the installation please make sure that al...

Page 13: ...ole Hot water outlet Condensate drainage Cold water inlet G M Hot water outlet G M Condensate drainage 18mm 8 2 DIMENSIONS Air outlet Air inlet The lower part of the unit is white RAL9003 and the uppe...

Page 14: ...that hold the bottom central plate and remove the cover 1 Manual reset thermostat 2 Electric heater and magnesium anode 8 5 HOW TO REPLACE THE MAGNESIUM ANODE The Magnesium anode is an anti corrosion...

Page 15: ...he rules reported on this manual can create dangerous situations After receiving the unit immediately check its integrity The unit left the factory in perfect condition any eventual damage has to be q...

Page 16: ...In case the unit is used without air ejection duct verify that the installation room has got a volume not less than 10m3 with adequate ventilation Please note that the temperature of the expelled air...

Page 17: ...icity cables 2 Insert the supplied rawlplugs in the holes and fix the support bracket through the screws and washers 3 Secure the mounting bracket of the unit Make sure that is centered on the wall 4...

Page 18: ...e floor using the special anti vibration feet NOT supplied with the unit See the image below Vibration damper SUPPORTS for floor installation Vibration damper supports for floor installation If air in...

Page 19: ...to be operated regularly to remove lime deposits and to verify that it is not blocked Please beware of burn because of the high temperature of water The expansion tank with capacity suitably sized to...

Page 20: ...is clean after the unit has been installed and then check it periodically Perform the drainage piping work according to the installation instruction If there is a defect in the drainage piping work w...

Page 21: ...om water that may spatter In order to get access to the electrical box 1 remove the front part of the unit twist off the screws placed on the sides using a suitable long screwdriver it is possible to...

Page 22: ...o not modify the internal wiring of the unit otherwise the warranty will terminate immediately 11 APPLIANCE OPERATION 11 1 USER INTERFACE 11 2 OPERATION 1 Power ON When turning ON the power the whole...

Page 23: ...r off setting Press the and buttons to set the minutes and press to confirm the activation of the ON and then press the clock button to quit the timer setting mode The timer ON and timer OFF icons wil...

Page 24: ...equipped with the manual defrost control 5 Heating The icon indicates that the current operation mode of the system is heating by the heat pump 6 Heating and electric heater The presence of both icon...

Page 25: ...re when the water temperature of the tank becomes equal or higher than 85 C the electrical heater stops unless the protection is manually reset For the manual reset of the protection remove the bottom...

Page 26: ...er 4 The parameters 4 and 5 control the anti legionella cycle temperature versus time We recommend to respect the above guidelines if you want to change them Please remember that to keep the temperatu...

Page 27: ...h the maximum admissible temperature value given by the climatic curve and then the unit will operate according to the highest one of the comparison between both values P 20 1 the setting temperature...

Page 28: ...it 09 Maximum defrosting cycle time 1 12 min 8 min Only technician of TAC can change it 10 Operating mode of the electronic expansion valve 0 auto 1 manual 0 Only technician of TAC can change it 11 S...

Page 29: ...3 The electronic expansion valve assembly blocked 4 Too much refrigerant 5 The HP switch damaged 6 The uncompressed gas is in refrigerant system 1 Check if the air inlet temp is over the working limit...

Page 30: ...rect operation of the electric heater for the purpose of anti Legionella cycle Be sure to make a diagnosis with samples of water token from the critical points the whole hydraulic circuit x Check out...

Page 31: ...to proper collecting centre compressors lubricating oil has to be collected and sent to proper collecting centre the casing and various components if no longer serviceable must be dismantled and divi...

Page 32: ...o install externally Bar 8 Material of of the inner surface of the tank S235JR with double layer vitrification Auxiliary electric heater kW 1 5 Electronic expansion valve si Magnesium anode si Materia...

Page 33: ...tervention of the safety and protection devices In any case as regards high temperatures for water if the setting temperature is outside the operating region the unit will automatically adapt its set...

Page 34: ...CALIDO Sanitary water heat pump 34 17 WIRING DIAGRAM Please refer to the wiring diagram sticked on the electric box...

Page 35: ...door LWA 49 dB A Precauzioni di installazione e manutenzione Precautions for installation and maintenance Per le indicazioni relative all installazione e alla manutenzione riferirsi ai capitoli dedica...

Page 36: ......

Reviews: