background image

CALIDO

 

Sanitary

 

water

 

heat

 

pump

 

 

32 

15

 

TECHNICAL

 

CHARACTERISTICS

 

TECHNICAL

 

DATA

 

CALIDO

 

110

 

Power

 

supply

 

V/Ph/Hz

 

220

240/1/50

 

Water

 

tank

 

real

 

capacity

 

L

 

110

 

Heating

 

capacity

 

W

 

850*

 

(+1500**)

 

Rated

 

power

 

input

 

W

 

236*

 

(+1500**)

 

Nominal

 

current

 

A

 

1.14*

 

(+6.5**)

 

SCOP

DHW

 

(ERP)

 

***

 

W/W

 

3.01

 

Max

 

power

 

input

 

W

 

400

 

(+1500**)

 

Max

 

current

 

A

 

1.81

 

(+6.5**)

 

Heating

 

time

 

with

 

cold

 

tank

 

***

 

h:min

 

6:53

 

Potenza

 

assorbita

 

in

 

stand

 

by

 

(***)

 

W

 

13.4

 

Max.

 

outlet

 

water

 

temperature

 

(without

 

E

heater

 

operation)

 

°C

 

60

 

Max

 

water

 

temperature

 

**

 

°C

 

70**

 

Minimum

 

temperature

 

for

 

starting

 

°C

 

10

 

Working

 

ambient

 

temperature

 

°C

 

5

 

~

 

+43

 

Refrigerant

 

max.

 

discharge

 

pressure

 

bar

 

25

 

Refrigerant

 

max.

 

suction

 

pressure

 

bar

 

0,2

 

Refrigerant

 

type

 

R134a

 

Refrigereant

 

GWP

 

1430

 

Refrigerant

 

charge

 

g

 

650

 

Amount

 

fluorinated

 

greenhouse

 

gases

 

tCO

2

 

eq

 

0,93

 

Compressor

 

Type

 

Rotary

 

Oil

 

(type)

 

68HES

H

 

Oil

 

(q.ty)

 

376

 

ml

 

Fan

 

motor

 

Type

 

AC

 

W

 

20

 

Nominal

 

air

 

flow

 

m

3

/h

 

300

 

Available

 

static

 

pressure

 

Pa

 

60

 

Air

 

flow

 

at

 

60

 

Pa

 

m

3

/h

 

170

 

Duct

 

diameter

 

mm

 

DN

 

125

 

Max

 

allowed

 

pressure

 

water

 

side

 

bar

 

6

 

Relief

 

valve

 

setpoint

 

(to

 

install

 

externally)

 

Bar

 

8

 

Material

 

of

 

of

 

the

 

inner

 

surface

 

of

 

the

 

tank

 

 

S235JR

 

with

 

double

layer

 

vitrification

 

Auxiliary

 

electric

 

heater

 

kW

 

1.5

 

Electronic

 

expansion

 

valve

 

si

 

Magnesium

 

anode

 

si

 

Material

 

of

 

the

 

heat

 

pump

 

exchanger

 

(condenser)

 

Copper

 

Chilled

 

water

 

input

 

inch

 

G

 

1/2

 

 

male

 

Hot

 

water

 

outlet

 

inch

 

G

 

1/2

 

 

male

 

Condensed

 

water

 

outlet

 

Flexible

 

plastic

 

tube

 

18

 

mm

 

Drainage

 

inch

 

To

 

be

 

installed

 

externally

 

Power

 

cable

 

length

 

m

 

1,5

 

IP

 

protection

 

class

 

IPX1

 

Net

 

dimensions

  

LxHxW

 

mm

 

500x520X1406

 

Packing

 

Dimensions

 

mm

 

550x550x1460

 

Net

 

Weight

 

Kg

 

72.0

 

Peso

 

con

 

serbatoio

 

pieno

 

d’acqua

 

Kg

 

182

 

Gross

 

Weight

 

Kg

 

84.0

 

Sound

 

power

 

****

 

dB

 

(A)

 

48.5

 

NOTE:

 

*

 

Heating

 

capacity,

 

power

 

input

 

based

 

on

 

the

 

following

 

conditions:

 

    

Ambient

 

temperature

 

20°C,

 

water

 

temperature

 

from

 

15°C

 

to

 

55°C

 

(obtained

 

results

 

by

 

internal

 

laboratory

 

tests

 

based

 

on

 

the

 

uniform

 

reintegration

 

of

 

the

 

tank

 

temperature).

 

**In

 

relazione

 

alla

 

resistenza

 

ausiliaria.

 

Durante

 

il

 

ciclo

 

di

 

disinfezione,

 

la

 

temperatura

 

viene

 

innalzata

 

a

 

70°C

 

dalla

 

resistenza

 

ausiliaria

 

***

 

Obtained

 

with

 

the

 

tank

 

stored

 

at

 

an

 

ambient

 

temperature

 

of

 

20°C,

 

with

 

air

 

inlet

 

of

 

the

 

duct

 

at

 

7°C

 

and

 

all

 

other

 

parameters

 

in

 

accordance

 

with

 

EN

 

16147.

 

****According

 

to

 

EN

 

12102:

 

ducted

 

unit

 

in/out

 

2m.

 

 
 
 
 

Summary of Contents for CALIDO 110

Page 1: ...ical specifications provided in this manual It is besides forbidden the reproduction under any form of the texts and of the figures contained in this manual This manual is a translation from the offic...

Page 2: ...Catalogue Katalog Catalogue MUI01110L8420 02 Serie Series Serie Serie S rie SANITARY WATER HEAT PUMP Possible wasted electrical or electronic devices products should not be located together with norm...

Page 3: ...EPIMENTO 2014 30 UE 2014 35 UE EVENTUALI ALTRE DIRETTIVE EUROPEE E NORME ARMONIZZATE APPLICATE ALL ATTREZZATURA EMC 2004 108 EC IEC 60335 2 21 IEC 60335 2 40 EN 55014 1 EN 61000 3 2 EN 61000 3 11 IS I...

Page 4: ...8 4 ACCESS TO THE BOTTOM PART 14 8 5 HOW TO REPLACE THE MAGNESIUM ANODE 14 8 6 REGULATION THERMOSTAT OF THE ELECTRIC HEATER 15 8 7 SCHEMATIC OVERVIEW OF THE WATER AND GAS CIRCUIT 15 9 INSTALLATION 15...

Page 5: ...5 5 Defrosting cycle 27 11 5 6 Anti freeze protection 27 11 6 PARAMETERS CONTROL AND SETTING 28 11 7 MALFUNCTIONING OF THE UNIT AND ERROR CODES 29 12 MAINTENANCE AND PERIODICAL CONTROLS 30 12 1 ENVIRO...

Page 6: ...or transcription The customer shall store any updated copy of the manual or parts of it delivered by the manufacturer as an attachment to this manual The company is available to give any detailed inf...

Page 7: ...d a number of directives on workplace s health and safety which include 89 391 CEE 89 686 CEE 2009 104 CE 86 188 CEE and 77 576 CEE directives Every employer shall implement such provisions and ensure...

Page 8: ...ymptoms may include loss of mobility and or consciousness Victims may not be aware of asphyxia Low concentration can have a narcotic effect The symptoms may include dizziness headache nausea and loss...

Page 9: ...nments a breathing apparatus or mask breathing air supply system must be used EN 137 Respiratory protective devices Self contained open circuit compressed air breathing apparatus with full face mask H...

Page 10: ...s it can contribute to the greenhouse effect It contains fluorinated greenhouse gases regulated by the Kyoto protocol DISPOSAL CONSIDERATIONS 13 1 Waste treatment methods Refer to the supplier gas rec...

Page 11: ...et makes the unit suitable for various ways of connections With different ways of installation the unit can work as just a heat pump but also as a fresh air blower a dehumidifier or an energy recovery...

Page 12: ...ple when you have the production of a photovoltaic system maximizing the self consumption and energy efficiency 7 ITEMS INSIDE THE PACKING BOX Before starting the installation please make sure that al...

Page 13: ...ole Hot water outlet Condensate drainage Cold water inlet G M Hot water outlet G M Condensate drainage 18mm 8 2 DIMENSIONS Air outlet Air inlet The lower part of the unit is white RAL9003 and the uppe...

Page 14: ...that hold the bottom central plate and remove the cover 1 Manual reset thermostat 2 Electric heater and magnesium anode 8 5 HOW TO REPLACE THE MAGNESIUM ANODE The Magnesium anode is an anti corrosion...

Page 15: ...he rules reported on this manual can create dangerous situations After receiving the unit immediately check its integrity The unit left the factory in perfect condition any eventual damage has to be q...

Page 16: ...In case the unit is used without air ejection duct verify that the installation room has got a volume not less than 10m3 with adequate ventilation Please note that the temperature of the expelled air...

Page 17: ...icity cables 2 Insert the supplied rawlplugs in the holes and fix the support bracket through the screws and washers 3 Secure the mounting bracket of the unit Make sure that is centered on the wall 4...

Page 18: ...e floor using the special anti vibration feet NOT supplied with the unit See the image below Vibration damper SUPPORTS for floor installation Vibration damper supports for floor installation If air in...

Page 19: ...to be operated regularly to remove lime deposits and to verify that it is not blocked Please beware of burn because of the high temperature of water The expansion tank with capacity suitably sized to...

Page 20: ...is clean after the unit has been installed and then check it periodically Perform the drainage piping work according to the installation instruction If there is a defect in the drainage piping work w...

Page 21: ...om water that may spatter In order to get access to the electrical box 1 remove the front part of the unit twist off the screws placed on the sides using a suitable long screwdriver it is possible to...

Page 22: ...o not modify the internal wiring of the unit otherwise the warranty will terminate immediately 11 APPLIANCE OPERATION 11 1 USER INTERFACE 11 2 OPERATION 1 Power ON When turning ON the power the whole...

Page 23: ...r off setting Press the and buttons to set the minutes and press to confirm the activation of the ON and then press the clock button to quit the timer setting mode The timer ON and timer OFF icons wil...

Page 24: ...equipped with the manual defrost control 5 Heating The icon indicates that the current operation mode of the system is heating by the heat pump 6 Heating and electric heater The presence of both icon...

Page 25: ...re when the water temperature of the tank becomes equal or higher than 85 C the electrical heater stops unless the protection is manually reset For the manual reset of the protection remove the bottom...

Page 26: ...er 4 The parameters 4 and 5 control the anti legionella cycle temperature versus time We recommend to respect the above guidelines if you want to change them Please remember that to keep the temperatu...

Page 27: ...h the maximum admissible temperature value given by the climatic curve and then the unit will operate according to the highest one of the comparison between both values P 20 1 the setting temperature...

Page 28: ...it 09 Maximum defrosting cycle time 1 12 min 8 min Only technician of TAC can change it 10 Operating mode of the electronic expansion valve 0 auto 1 manual 0 Only technician of TAC can change it 11 S...

Page 29: ...3 The electronic expansion valve assembly blocked 4 Too much refrigerant 5 The HP switch damaged 6 The uncompressed gas is in refrigerant system 1 Check if the air inlet temp is over the working limit...

Page 30: ...rect operation of the electric heater for the purpose of anti Legionella cycle Be sure to make a diagnosis with samples of water token from the critical points the whole hydraulic circuit x Check out...

Page 31: ...to proper collecting centre compressors lubricating oil has to be collected and sent to proper collecting centre the casing and various components if no longer serviceable must be dismantled and divi...

Page 32: ...o install externally Bar 8 Material of of the inner surface of the tank S235JR with double layer vitrification Auxiliary electric heater kW 1 5 Electronic expansion valve si Magnesium anode si Materia...

Page 33: ...tervention of the safety and protection devices In any case as regards high temperatures for water if the setting temperature is outside the operating region the unit will automatically adapt its set...

Page 34: ...CALIDO Sanitary water heat pump 34 17 WIRING DIAGRAM Please refer to the wiring diagram sticked on the electric box...

Page 35: ...door LWA 49 dB A Precauzioni di installazione e manutenzione Precautions for installation and maintenance Per le indicazioni relative all installazione e alla manutenzione riferirsi ai capitoli dedica...

Page 36: ......