Magnet limit sensors are sold separately.
The
GRAY
limit sensor
MUST
be mounted
on the
OPEN POSITION
on the Back Plate on
operator. The limit sensor magnets
MUST
be
installed on
BOTH
ends of chain to indicate
the
OPEN
and
CLOSE
positions of the gate.
They will activate the corresponding
LIMIT
SENSOR
(Gray-Open or Black-Close) when
they move within range, stopping the gate at
the desired positions.
Limit Sensor
Magnet
Gate
Bracket
Limit Sensor
Magnet
Limit Sensor
Mounting Holes
GRAY
Limit Sensor
Gate
Bracket
IMPORTANT:
LEDs
MUST
light up when gate
reaches
OPEN
and
CLOSE
positions or operator
WILL NOT
learn gate positions. If gate positions
are not learned, gate cycling speed will
remain
slow during normal operation.
IMPORTANT:
Limit Sensor Magnets
MUST
be installed on
BOTTOM
of chain
as shown.
BLACK
Limit Sensor
Plu
g
Plu
g
Install Limit Sensors:
Push and
HOLD
the
JOG LEFT
or
JOG RIGHT
buttons accordingly to move the gate (release
the button to stop gate).
JOG Left/Right Buttons
Use JOG Left/Right Buttons for installation
1.
Install
GRAY
sensor on
OPEN
position and
BLACK
sensor on
CLOSE
position as shown.
2.
JOG gate to
CLOSE
position.
3.
Mark magnet position on chain.
4.
JOG gate open slightly and install magnet.
5.
JOG gate to
OPEN
position.
6.
Mark magnet position on chain.
7.
JOG gate closed slightly and install magnet.
8.
Gate positions can now be learned, see .
Plu
g
OPEN
JOG
LEFT
RIGHT
optional magnet limit sensors
CLOSING
CLOSING
OPENING
RD
OTOR
VER
OAD
ERD
MOTOR
OVER
LOAD
MAX
OFF
MAX
SENSE
BATTERY
BACKUP MODE
SENSITIVITY
MOTION CONTROL
OPEN
GATE SPEED
MAG
LOCK
UL
ENTRAP
PRIMARY/
SECONDARY
LINK
STOP
CLOSE
MOTOR
INPUTS
CLOSE
TIMER
MAGLOCK
DELAY
JOG
ACE
ERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
LINK
OK
MOTOR
POSITION
INPUTS
SLIDER
LIMIT
SWING
LIMIT
GND
OPEN ONLY
NC
OPEN ONLY
10K
PHOTO CLS
NC
OPEN/CLS
NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG RIGHT
JOG LEFT
TAMPER IN
TAMPER NO
GATE DISABLE
MANUAL RELEASE
GND
(-)
(+)
CLOSE
COM
COM
STOP
OPEN
CLS ONLY
10K
OPEN/CLS
10K
12VDC OUT
NO
COM
NC
LEFT
ON/OFF
BATTERY
RIGHT
QUICK
CLOSE
OPEN
LEFT
OPEN
RIGHT
GATE
OFF
MIN
MIN
MAX
MAX
ON
OFF
2.5 sec
1.5 sec
MATRIX III
3
1
14
16
MIN
12
9
7
UL SENSOR N.C.
UL SENSOR 10K
GATE OPEN
COM
GATE CLOSED
MIN
MATRIX III
SWING / SLIDE
Rear Mounting Position
Front Mounting Position
Back
View
Back
Plate
Back
Plate
Back
View
Limit Sensor
Magnet
GRAY Open Position
GRAY Open Position
Black Close Position
Black Close Position
Limit Sensor
Magnet
Limit Sensor
Magnet
Limit Sensor
Magnet
IMPORTANT:
Gray Limit sensor
MUST
be in the
OPEN position
on the operator.
CLOSE
LED lights when
sensing a limit
sensor magnet.
L
I
M
I
T
S
E
N
S
O
R
Back Plate
7
Limit Sensor
Matrix III Connection
2
8
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install
Version 7a
Summary of Contents for 1500 PRO
Page 30: ...a...
Page 33: ......
Page 37: ...30 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...
Page 38: ...31 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...
Page 39: ...32 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...