background image

EXIT PWR

ALARM

POWER /

SOLAR IN

BATTERY

INPUT

OPENING

CLOSING

CLOSING

OPENING

ERD

OBD PORT

BLACK BOX

PROGRAMMING

SOLAR MODE

PROGRAM

MOTOR

OVER

LOAD

ERD

MOTOR

OVER

LOAD

MAX

OFF

MAX

SENSE

MAX

SENSE

BATTERY

BACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

GATE SPEED

MAG

LOCK

UL

ENTRAP

PRIMARY/

SECONDARY

LINK

STOP

CLOSE

MOTOR

INPUTS

CLOSE

TIMER

MAGLOCK

DELAY

JOG

BATTERY

TEST

INPUT

ERROR

BATTERY

BATTERY

IN USE

REPLACE

BATTERY

LEAVE

CLOSED

LEAVE

OPEN

OPEN

1 TIME

BATTERY VOLTAGE

E

F

1/2

RESET /

MANUAL

RELEASE

ID

PLUG

LINK

OK

MODULE

PORT

MOTOR

POSITION

INPUTS

SLIDER

LIMIT

SWING

LIMIT

GND

OPEN ONLY 

NC

OPEN ONLY 

10K

PHOTO CLS 

NC

OPEN/CLS 

NC

GND

12VDC OUT

GND

GND

GND

GND

GND

GND

JOG RIGHT

JOG LEFT

TAMPER IN

TAMPER NO

GATE DISABLE

MANUAL RELEASE

KEYPAD / CARD

GND

(-)

(+)

GND

GND

MAX OPEN

FIRE DEPT

RADIO GND

RADIO SIGNAL

STRIKE

CLOSE

COM

COM

STOP

OPEN

CLS ONLY 

10K

OPEN/CLS 

10K

12VDC OUT

NO

COM

NC

ID PLUG

ERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

GND

LOOP PWR

OFF

PRIMARY

LEFT

ON/OFF

BATTERY

RIGHT

SECONDARY

ON

QUICK

CLOSE

OPEN

LEFT

OPEN

   RIGHT

GATE

OFF

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

MIN

MIN

MAX

MAX

ON

OFF

2.5 sec

1.5 sec

FAULTS

OPERATOR

MATRIX III

OFF

OFF

3

1

14

16

MIN

16

MIN

12

9

7

3

1

14

12

9

7

UL SENSOR N.C.

UL SENSOR 10K

POWER

MODE A

MODE B

EXIT

LOOP

LOOP

LOOP

CENTER

SAFETY

GATE OPEN

COM

GATE CLOSED

MIN

MATRIX III
SWING / SLIDE

EXIT PWR

ALARM

POWER /

SOLAR IN

BATTERY

INPUT

OPENING

CLOSING

CLOSING

OPENING

ERD

OBD PORT

BLACK BOX

PROGRAMMING

SOLAR MODE

PROGRAM

MOTOR

OVER

LOAD

ERD

MOTOR

OVER

LOAD

MAX

OFF

MAX

SENSE

MAX

SENSE

BATTERY

BACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

GATE SPEED

MAG

LOCK

UL

ENTRAP

PRIMARY/

SECONDARY

LINK

STOP

CLOSE

MOTOR

INPUTS

CLOSE

TIMER

MAGLOCK

DELAY

JOG

BATTERY

TEST

INPUT

ERROR

BATTERY

BATTERY

IN USE

REPLACE

BATTERY

LEAVE

CLOSED

LEAVE

OPEN

OPEN

1 TIME

BATTERY VOLTAGE

E

F

1/2

RESET /

MANUAL

RELEASE

ID

PLUG

LINK

OK

MODULE

PORT

MOTOR

POSITION

INPUTS

SLIDER

LIMIT

SWING

LIMIT

GND

OPEN ONLY 

NC

OPEN ONLY 

10K

PHOTO CLS 

NC

OPEN/CLS 

NC

GND

12VDC OUT

GND

GND

GND

GND

GND

GND

JOG RIGHT

JOG LEFT

TAMPER IN

TAMPER NO

GATE DISABLE

MANUAL RELEASE

KEYPAD / CARD

GND

(-)

(+)

GND

GND

MAX OPEN

FIRE DEPT

RADIO GND

RADIO SIGNAL

STRIKE

CLOSE

COM

COM

STOP

OPEN

CLS ONLY 

10K

OPEN/CLS 

10K

12VDC OUT

NO

COM

NC

ID PLUG

ERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

LOOP PWR

OFF

PRIMARY

LEFT

ON/OFF

BATTERY

RIGHT

SECONDARY

ON

QUICK

CLOSE

OPEN

LEFT

OPEN

   RIGHT

GATE

OFF

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

MIN

MIN

MAX

MAX

ON

OFF

2.5 sec

1.5 sec

OPERATOR

MATRIX III

OFF

3

1

14

16

MIN

16

MIN

12

9

7

3

1

14

12

9

7

UL SENSOR N.C.

UL SENSOR 10K

POWER

MODE A

LOOP

LOOP

LOOP

GATE OPEN

COM

GATE CLOSED

MIN

MATRIX III
SWING / SLIDE

gate tamper feature

Many different safety devices can be wired to the 

GATE TAMPER

. After device is wired to relay, it 

MUST

 be 

ARMED

 to function.

Security

Camera

EX

PRIMARY/

SECONDARY

LINK

OK

D

ND

G

NUAL RELEASE

AD / CARD

G

ND

(-

)

(+)

CLO

CO

STOP

O

PEN

24VDC OUTPUT

OUTPUT

GND

LOOP PWR

PRIMARY

SECONDA

O

LOOP

LOOP

ALARM

OSING

PROGRAMM

LAR MODE

PROGRAM

OPE

GATE SPEED

EN

RESET /

MANUAL

RELEASE

ID

G

MODU

PORT

ID PLUG

ERROR

QUICK

CLOSE

GAT

OFF

1

2

3

4

5

6

1

2

3

4

5

6

MIN

MAX

ON

MODE A

Wiring Gate Tamper

The 

GATE TAMPER

 can be used for various functions such as 

turning a warning light, siren or camera on when the gate is 
tampered with (Vandalized Gate).
The gate operator defines a “Vandalized Gate” as 

UNAUTHORIZED

 

movement of the gate. This can occur if the chain is dropped and 
gate is manually moved from the 

closed position 

or the gate is 

forced open from the 

closed position without authorization.

TAMPER NO/Com Relay:

 Connect a warning light, siren, camera or 

an existing alarm system to relay. 

TAMPER IN/GND Input:

 Connect a sensor device to input. When 

Tamper In/GND gets triggered, device that is wired to Tamper relay 
(NO/Com) will activate. 

Arm Gate Tamper (Turn ON)

Siren

Warning

Light

Motion
Sensor

Power

Power

Existing

Building

Alarm

System

The 

GATE TAMPER

 is factory set to 

OFF 

(Unarmed). It 

MUST

 be turned 

ON

 (Armed) or safety device connected to the 

GATE TAMPER 

relay will 

NOT

 activate.

Press and 

HOLD

 the 

STOP

 button while simultaneously pressing

the 

PROGRAM

 button. Hold 

BOTH

 buttons down until

Gate Tamper LEDs light up then turn OFF and a beep is heard.

Gate Tamper

 is now 

ARMED (ON)

.

 NOTE:

 

DO NOT

 press the 

PROGRAM

 button before 

 the 

STOP

 button or Gate Tamper will 

NOT

 Arm.

To 

UNARM (Turn OFF) Gate Tamper 

repeat above step.

When 

GATE TAMPER

 is triggered, the 

OPERATOR ALARM

 and 

GATE TAMPER

 

relay will activate. The operator will shut 
down all operating functions.
The alarm reset button 

MUST

 be pressed to 

turn 

OFF

 the alarm and reset the operator.

If 

GATE TAMPER

 is armed and relay is connected to 

an existing building alarm system, then they will get a 
triggering of their alarm system and should be 
notified of the situation.

Alarm Reset Button

GND

GND

JOG LEFT

JOG RIGHT

TAMPER IN

TAMPER NO

COM

N

N

N

O

O

O

O

O

O

O

O

Gate Tamper LEDs

Press buttons together

1

5

UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install 

Version 7a

Summary of Contents for 1500 PRO

Page 1: ...om 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA CONFORMS TO UL STD 325 MAX 1500 PRO 2200 PRO UL CLASS I II III IV MAX F18 PRO UL CLASS III IV ONLY CERTIFIED TO CAN CSA...

Page 2: ...t lors de l ouverture et de la fermeture la barri re doit tre install e dans un endroit o la barri re et les structures avoisinantes sont suffisamment loign es l une de l autre Les barriers battantes...

Page 3: ...1 Au moins un capteur de contact doit tre situ o il existe un risque de coincement ou d obstruction comme sur le bord d ouverture sur le bord de fermeture et sur les poteaux mont s sur l int rieur ou...

Page 4: ...etest the gate operator properly can increase the risk of injury or death 4 V rifiez le fonctionnement de l ouvre barri re une fois par mois Le sens de la course DOIT s inverser lorsque la barri re en...

Page 5: ...25 model classifications A Inherent entrapment protection system B1 Provision for connection of a non contact sensor photoelectric sensor or the equivalent B2 Provision for connection of a contact sen...

Page 6: ...stalled where entrapment or pinch point exist A minimum of TWO entrapment protection sensors MUST be installed ONE in EACH direction of gate travel or operator will NOT function Physical Stops Install...

Page 7: ...29 UL 325 Class of Operation MAX 1500 PRO 2200 PRO Class I II III IV MAX F18 PRO Class III IV ONLY Gate Type Vehicular Slide Gate Max Gate Length 50 ft Max Gate Weight MAX 1500 PRO 1500 lbs Level Gate...

Page 8: ...round to avoid flooding Concrete Depth Note The heavier the gate the deeper the concrete pad should be At least two feet recommended for heavier gate Secure gate operator to concrete pad with four 4 1...

Page 9: ...or is NOT parallel to gate Chain is NOT parallel to gate DO NOT mount chain bracket too high on gate NO NO YES YES YES YES Drive Gear NOTE The chain should sag no more than one 1 inch per 10 feet of t...

Page 10: ...75 7 5 7 5 6 75 Cover 1 5 4 5 6 5 8 625 12 75 Conduit Area Outside Property Inside Property Input Power Physical Stop Conduit Run Operator MUST be level Concrete Pad Check local building codes in your...

Page 11: ...heel Approx 1 5 Pulley Wheel Safety Cover Gate YES YES Modify Cover for Rear Mounting Position 16 5 Cut out cover between new hole and existing chain exit slot Make sure cuts are plumb with existing c...

Page 12: ...Amp Select Input Voltage 115VAC or 230VAC 1 1 5 V MAX Toroid Box ac input power 2 GFCI Outlet NOT provided DANGER HIGH VOLTAGE Additional Gang Box Choose either 115V or 230V setting on input AC power...

Page 13: ...r or F Bat ter y Mo dul e Ground within 3 ft of operator Any of the THREE Chassis Grounds can be used They are located next to the gear reducer DO NOT remove any existing green ground wires 1 2 3 Grou...

Page 14: ...C UL SENSOR 10K entrapment protection wiring 5 Entrapment Protection Device Options and Locations Beam 5 or LESS from CLOSED gate Conduit Entrapment Area CLOSING Direction Photocell Wall Gate Closed...

Page 15: ...Mini Edge Contact Edge Sensor ASO Edge Thin Edge MAX Edge 1 Contact Edge Sensor Test Connected Sensors Test ALL connected entrapment protection sensors using learn mode 1 Press and HOLD the STOP butt...

Page 16: ...PEN GATE SPEED MAG LOCK UL ENTRAP PRIMARY SECONDARY LINK STOP CLOSE MOTOR INPUTS CLOSE TIMER MAGLOCK DELAY JOG BATTERY TEST INPUT ERROR BATTERY BATTERY IN USE REPLACE BATTERY LEAVE CLOSED LEAVE OPEN O...

Page 17: ...ter clockwise to reduce gate sensitivity while testing ERD until desired results is attained LED remains OFF for all but position 1 IMPORTANT When satisfied with ERD adjustment cycle the gate 3 or 4 t...

Page 18: ...Detectors to HIGH sensitivity to avoid false trigger NOTE DO NOT select the PULSED output option for Loop Detectors EDI Loop Detector EDI Loop Detector Low Current Draw ON 1 2 3 4 5 6 7 8 5 Op tim um...

Page 19: ...en wired to indicated inputs MUST be LEARNED BEFORE they will be MONITORED 2 Press and HOLD the STOP button then the OPEN button together until beeping is heard learn mode begins DO NOT press the OPEN...

Page 20: ...EN OPEN 1 TIME BATTERY VOLTAGE E F 1 2 RESET MANUAL RELEASE ID PLUG LINK OK MODULE PORT MOTOR POSITION INPUTS SLIDER LIMIT SWING LIMIT OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN CLS NC GND 12VDC OUT...

Page 21: ...servicing the operator to prevent the switch from accidentally being turned ON during normal operation Plug the wire back in and turn ON the switch only while servicing the operator This can prevent...

Page 22: ...3 4 5 6 7 8 9 10 1 2 3 4 5 6 MIN MIN MAX MAX ON OFF 2 5 sec 1 5 sec OPERATOR MATRIX III OFF 3 1 14 16 MIN 16 MIN 12 9 7 3 1 14 12 9 7 UL SENSOR N C UL SENSOR 10K POWER MODE A LOOP LOOP LOOP GATE OPEN...

Page 23: ...SOR 10K POWER MODE A MODE B EXIT LOOP LOOP LOOP CENTER SAFETY GATE OPEN COM GATE CLOSED MIN MATRIX III SWING SLIDE Gate Tamper Relay The GATE TAMPER is factory set to OFF Unarmed See previous page for...

Page 24: ...IGHT JOG LEFT TAMPER IN TAMPER NO GATE DISABLE MANUAL RELEASE KEYPAD CARD GND GND GND MAX OPEN FIRE DEPT RADIO GND RADIO SIGNAL STRIKE CLOSE COM COM STOP OPEN CLS ONLY 10K OPEN CLS 10K 12VDC OUT NO CO...

Page 25: ...GND GND GND MAX OPEN FIRE DEPT RADIO GND RADIO SIGNAL STRIKE CLOSE COM COM CLS ONLY 10K OPEN CLS 10K 12VDC OUT NO COM NC ERROR 24VDC OUTPUT 12VDC OUTPUT GND GND GND LOOP PWR OFF PRIMARY LEFT ON OFF B...

Page 26: ...RI_MC Photo Cell Ac vated Fri 07 11 2014 10 57 21 INFO Radio Input Deac vated Fri 07 11 2014 10 57 21 INFO Radio Input Ac vated Fri 07 11 2014 10 56 46 WARNING PRI_MC Tamper Reported Fri 07 11 2014 10...

Page 27: ...TERY IN USE LED is ON and BATTERY BACK UP MODE switch is set to Leave Open then battery may be too low and gate is kept OPEN If BATTERY IN USE LED is ON and BATTERY BACK UP MODE switch is set to OPEN...

Page 28: ...S ONLY 10K LED is ON PHOTO CLS LED is flashing CLS ONLY 10K LED is flashing OPEN ONLY LED is ON OPEN ONLY LED is FLASHING MAX SENSE LED is ON MANUAL RELEASE RESET LED is ON but manual release is not w...

Page 29: ...flashing Loop fault condition check if SAFETY loop wires are connected into to loop input connector properly Check if SAFETY loops are wired in series Check if loop detector is inserted properly in L...

Page 30: ...a...

Page 31: ...protection device MUST be MONITORED by the gate operator Installation Steps 1 Set DIP switches on receiver 2 Install jumper on receiver 3 Wire Matrix III 12VDC OUT power to receiver 4 Wire PHOTO CLS...

Page 32: ...nd to an obstruction lower the sensitivity by turning adjustment counter clockwise Transmitter TX Secondary Matrix III Receiver RX Normally Closed PHOTO CLS NC Common GND Green LED Green LED NOComNC J...

Page 33: ......

Page 34: ...NC Power NC Jog Left Jog Right External Alarm Reset Button Dry Contact Security Device PRESS to RESET ID Plug Specific for operator type REQUIRED Maglock Solenoid Lock Motion Sensor External Jog Left...

Page 35: ...hain 7 JOG gate closed slightly and install magnet 8 Gate positions can now be learned see Plug OPEN JOG LEFT RIGHT optional magnet limit sensors CLOSING CLOSING OPENING RD OTOR VER OAD ERD MOTOR OVER...

Page 36: ...GNAL STRIKE STOP OPEN ID PLUG ERROR 24VDC OUTPUT 12VDC OUTPUT GND GND GND LOOP PWR OFF PRIMARY SECONDARY ON QUICK CLOSE OPEN LEFT O R GATE OFF 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 MIN MIN MAX MAX ON FAULT...

Page 37: ...30 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...

Page 38: ...31 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...

Page 39: ...32 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...

Page 40: ...708 Tel 949 699 0220 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA SAFETY SENSORS REQUIRED MATRIX III CONFORMS TO UL STD 325 MAX 1500 PRO 2200 PRO UL CLASS I II III IV M...

Reviews: