EXIT PWR
ALARM
SOLAR IN
OPENING
O
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOR
OVER
LOAD
MAX
SENSE
S
ERD SENS
M
OP
TEST
RESET /
MANUAL
RELEASE
ID
PLUG
MODULE
PORT
GND
GND
GND
MANUAL RELEASE
KEYPAD / CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWR
OFF
PRIMARY
SECONDARY
ON
QUI
CLO
OFF
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
MIN
MAX
FAULTS
OPERATOR
OFF
OFF
16
MIN
3
1
14
12
9
7
POWER
MODE A
M
ODE B
EXIT
LOOP
LOOP
LOOP
CENTER
SAFETY
MAT
SWIN
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING
CLOSING
CLOSING
OPENING
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
PROGRAM
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
GATE SPEED
MAG
LOCK
UL
ENTRAP
PRIMARY/
SECONDARY
LINK
STOP
CLOSE
MOTOR
INPUTS
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
INPUT
ERROR
BATTERY
BATTERY
IN USE
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E
F
1/2
RESET /
MANUAL
RELEASE
ID
PLUG
LINK
OK
MODULE
PORT
MOTOR
POSITION
INPUTS
SLIDER
LIMIT
SWING
LIMIT
GND
OPEN ONLY
NC
OPEN ONLY
10K
PHOTO CLS
NC
OPEN/CLS
NC
GND
12VDC OUT
GND
GND
GND
GND
GND
GND
JOG RIGHT
JOG LEFT
TAMPER IN
TAMPER NO
GATE DISABLE
MANUAL RELEASE
KEYPAD / CARD
GND
(-)
(+)
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY
10K
OPEN/CLS
10K
12VDC OUT
NO
COM
NC
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP PWR
OFF
PRIMARY
LEFT
ON/OFF
BATTERY
RIGHT
SECONDARY
ON
QUICK
CLOSE
OPEN
LEFT
OPEN
RIGHT
GATE
OFF
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF
2.5 sec
1.5 sec
FAULTS
OPERATOR
MATRIX III
OFF
OFF
3
1
14
16
MIN
16
MIN
12
9
7
3
1
14
12
9
7
UL SENSOR N.C.
UL SENSOR 10K
POWER
MODE A
MODE B
EXIT
LOOP
LOOP
LOOP
CENTER
SAFETY
GATE OPEN
COM
GATE CLOSED
MIN
MATRIX III
SWING / SLIDE
Quick Close
Turned OFF -
Close timer
will close the gate at its
selected time.
Turned ON -
(In-ground loops required)
OPENING
gate
will stop and close after vehicle clears
safety loop
,
preventing UNAUTHORIZED entry.
Wire directly to
Matrix III board.
External
Loop
Detector
External Loop Detectors
In-Ground Loops
Connections
Loop Detector Rack
SAFETY
CENTER
EXIT
In-Ground Loops
loops & loop detectors
9
matrix III settings
10
Maglock Delay
Set to OFF
See next page to enable this feature.
Close Timer
1st click clockwise - Knob at MIN:
1/2 sec...
2nd click clockwise: 1 sec...
3rd click: 4 sec...
4th click: 8 sec... etc up to 60 sec. MAX.
Plug-In Loop Detectors
NOTE:
DO NOT
set Loop Detectors to
HIGH
sensitivity to avoid false trigger.
NOTE:
DO NOT
select the
PULSED
output option for Loop Detectors.
EDI
Loop Detector
EDI
Loop Detector
Low Current
Draw
ON
1
2
3
4
5
6
7
8
5 = Optim
um
Sen
s.
= Incr
ease Sens
.
= Decrease Sens
.
DEF
LECTOME
TER
POWER
ON = Normal
Pow
er
OFF= No Power
LED IN
DICA
TORS
DETECT
ON
= De
tect
OFF= No
Dete
ct
2 Hz Flash=Del
ay Ti
ming
SW1
SW2 Fr
equency
ON
ON =
Low
ON
OF
F
= M
edium
-Low
OFF
ON
=
Med
ium-H
igh
OFF
OF
F
= Hig
h
SW4
SW5 Output
B
ON
ON
=
Puls
e on Ent
ry
ON
OF
F
= B same
as
A
OFF
ON
=
Puls
e on
Exit
OFF
OF
F
= Loo
p Faul
t
SW3
ON
= Fail Secure
OFF
= Fa
il Sa
fe
SW6
ON
= 2 Secon
d De
lay
OFF
= No Delay
SW7
ON
= Nor
ma
l Pre
senc
e
OFF
= Infi
nite P
resen
ce
SW8
ON
= Sens
itiv
ity
Bo
os
t
OFF
= No
Sensit
ivity
Boos
t
Loop Fault
1 Flash =
Open Loo
p
2 Flashes= Sh
orted Lo
op
3 Flas
hes=25% chang
e
of In
ductanc
e
Both LED’
s Flashin
g=
Cu
rrent Loop Fault
PWR
LED
Flashing=
Pr
evious
Loo
p Faul
t
EDI
Tel: 480.968.6407
DEFLECTOME
TER
SENS
RES
ET
POWER
DETECT
EDI
SENS
LMA1800
OPTIONS
1
2
3
4
5
6
7
8
ON
OPTIONS
ON
1
2
3
4
5
6
7
8
5 = Optimum Se
ns.
= Increase Sens
.
= De
crease Se
ns.
DEFLECTO
METER
PO
WER
ON =
Normal Power
OFF=
No
Powe
r
LED INDICA
TORS
DETEC
T
ON =
Detect
OFF=
No
De
tect
2 Hz Fla
sh=
Delay
Timin
g
SW1 S
W2 Frequency
ON
ON = Low
ON
OFF = Medium-Lo
w
OFF
ON
= Mediu
m-High
OFF
OFF
= High
SW4
SW5
Output B
ON
ON = Pulse
on
Entr
y
ON OF
F = B
sam
e as
A
OF
F
ON
= P
uls
e on
Exit
OF
F
OFF
=
Loo
p Fault
SW3
ON
= Fail Secure
OF
F = Fai
l Safe
SW6
ON =
2 S
ec
ond
Dela
y
OFF
= N
o Dela
y
SW7
ON
=
Normal
Pre
senc
e
OFF
= I
nfinit
e Pres
en
ce
SW8
ON =
Se
nsi
tivity
Boos
t
OF
F =
N
o S
ens
itivit
y Bo
ost
Loop Fault
1 Flash = Open
Loo
p
2 Flashe
s= Shorted
Loop
3 Fl
ashes=
25%
chang
e
of
Induc
tanc
e
Both
LED’
s Flashing
=
Current
Loop
Faul
t
PWR
LED
Flas
hing=
Pre
vious
Loop
Faul
t
EDI
Tel: 480.968.6407
DEF
LECTOMETER
SENS
RESET
POW
ER
DETECT
ED
I
SENS
LMA1800-LP
1
2
3
4
5
6
7
8
O
N
Safety loops wired in series.
Safety
Loop
Safety
Loop
Exit
Loop
Battery Back-Up Mode
LEAVE OPEN
- After a power failure, gate will continue
to operate until battery power is drained. At this point,
the next open command, gate will remain
OPEN
. Gate
will
automatically
close after AC power is restored if
close timer is ON.
LEAVE CLOSED
- After a power failure, gate will
continue to operate until battery power is drained.
At this point, gate will remain
CLOSED.
OPEN 1 TIME
- After a power failure, gate
automati-
cally OPENS
and
REMAINS
OPEN.
When power is
restored, gate will
automatically
close.
Gate Speed
After gate positions have been
“
Learned
”, the gate will cycle at
the speed set on
“ GATE
SPEED”
settings.
11
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install
Version 7a
Summary of Contents for 1500 PRO
Page 30: ...a...
Page 33: ......
Page 37: ...30 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...
Page 38: ...31 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...
Page 39: ...32 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...