Entrée Bath Gen III -
MODEL MB-68 AV-XL
MAINTENANCE MANUAL
10-20-19
Page 44 of 51
450 E 32
nd
Ave – Fremont, NE 68025
800-798-5867 FAX: 402-721-3023
www.mastercarebath.com
ENTREE DOOR SEAL MAINTENANCE & REPLACEMENT INSTRUCTIONS
(Parts #211081 & 211082):
Note
: Read all instructions carefully and thoroughly. Refer to the attached Entree Door Seal drawing to reference details.
3.
Push door close button, bringing door up and stop once the Phillips head screw are visible on the side of the door.
(Fig. 1)
4.
Remove the casual water drain hose from the hose barb located on the bottom side of the door.
5.
Carefully remove the fiberglass door cover by removing the two Phillips head machine screws from each side of the
door (Fig: 1). Set the fiberglass door cover off to the side.
6.
Inspect if the the diverter seal door is damage or wear.
See
Entree Door Seal Diagram
Page45.
7.
Using a 9/16” wrench or 1/4" Allen wrench remove ONLY the top three door retainer bolts (Fig: 2) from each side of
the stainless steel door
(
Note
: Hold the door before removing the third bolt).
Gently lower the door down after the
third bolt is removed.
8.
If the seal is good condition as shown in (Fig: 4), clean out any accumulated debris between the seal and the stainless
steel door skin with a plastic putty knife. Inspect the door seal for damage or check if the door seal is permanently
compressed as shown in (Fig: 5). If the seal is damaged or permanently compressed, continue on to step 6. If
replacement of the seal is NOT necessary, continue on to steps 11, 13 and 14.
9.
Using a Phillips screwdriver, loosen all seal retainer bolts as shown in (Fig: 3). DO NOT remove the bolts.
10.
Remove the seal by gently pulling on one end until the entire seal is removed
(
Note
: If the seal is stuck, use a flat
screwdriver to pry up gently on the seal retainer)
.
11.
Clean the underside of the seal retainer and in between each screw with a plastic putty knife.
12.
Starting on one end of the seal retainer, slowly push the NEW seal under the retainer (Note: May be necessary to
gently pry up on the seal retainer with a flat screwdriver to get the seal under the retainer). Continue pushing the
seal under the retainer until the entire seal is installed.
13.
Push the seal towards the seal retainer and tighten each seal retainer bolt along the seal retainer (Fig: 3).
14.
Remove all tools from the stainless steel door. Lift up the stainless steel door and line up the holes in the door with
the holes in the tub (Fig: 2). Insert the three door retainer bolts into each side and tighten accordingly with a 9/16”
wrench or Allen wrench.
15.
Close the door all the way and proceed to fill the tub with water. Check for any leaks on the bottom side of the door.
If there are any leaks around the seal, repeat steps 4-10.
16.
Push the bottom of the fiberglass door cover in first then push in the top. Line up the holes in the fiberglass door
cover with the holes in the stainless steel door. Continue to insert the door retainer bolts into each side of the
fiberglass door cover. Tighten each bolt it contacts the fiberglass. If adjustment is needed, loosen and tighten each of
the bolts accordingly until the fiberglass cover is in proper alignment.
17.
Connect the casual water drain hose
to the hose barb on the bottom side of the door.