background image

LIMITED WARRANTY

Pinnacle Products International, Inc.

warrants this heater to

the original retail purchaser only, to be free from defects in mate-
rial and workmanship for a period of one (1) year from the date of
initial purchase. This product must be properly installed, main-
tained and operated in accordance with the instructions provided. 

Pinnacle Products International, Inc. 

requires reasonable proof

of your date of purchase from an authorized retailer or distributor.
Therefore, you should keep your sales slip, invoice, or cancelled
check from the original purchase. This Limited Warranty shall be
limited to the repair or replacement of parts, which prove defec-
tive under normal use and service within the warranty period, and
which 

Pinnacle Products International, Inc.

shall determine at

its reasonable discretion. 

This warranty does not apply to products purchased for rental
use.

This Limited Warranty does not cover any failures or operating
difficulties due to normal wear and tear, accident, abuse, misuse,
alteration, misapplication, improper installation or improper main-
tenance and service by you or any third party. Failure to perform
normal and routine maintenance on the heater, shipping damage,
damage related to insects, birds, or animals of any kind, and
damage due to weather conditions are also not covered. In addi-
tion, the Limited Warranty does not cover damage to the finish,
such as scratches, dents, discoloration, rust or other weather
damage, after purchase.

All transportation costs for the return of the damaged  product or
parts will be the responsibility of the purchaser. Upon receipt of
damaged item, 

Pinnacle Products International, Inc.

will exam-

ine the item and determine if defective. 

Pinnacle Products

International, Inc.

will repair or replace and return the item,

freight pre-paid. If 

Pinnacle Products International, Inc.

finds

the item to be in normal operating condition, or not defective, the 
item will be returned freight collect.This Limited Warranty is in

lieu of all other express warranties. 

Pinnacle Products

International, Inc.

disclaims all warranties for products that are

purchased from sellers other than authorized retailers or distribu-
tors. 
AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS WAR-
RANTY EXPIRES, 

Pinnacle Products International, Inc. 

DIS-

CLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING
WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR APPLICA-
TION. FURTHER, 

Pinnacle Products International, Inc. 

SHALL

HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY
THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE, INCI-
DENTAL, OR CONSEQUENTIAL DAMAGES. 

Pinnacle

Products International, Inc. 

assumes no responsibility for any

defects caused by third parties. This Limited Warranty gives the
purchaser specific legal rights; a purchaser may have other rights
depending upon where he or she lives. Some states do not allow
the exclusion or limitation of  special, incidental or consequential
damages, or limitations on how long a warranty lasts, so the
above exclusion and limitations may not apply to you.

Pinnacle Products International, Inc.

does not authorize any

person or company to assume for it any other obligation or liabili-
ty in connection with the sale, installation, use, removal, return,
or replacement of its equipment, and no such representations are
binding on 

Pinnacle Products International, Inc.

Always be sure to specify model number and serial number when
making any claim with 

Pinnacle Products International, Inc.

For your convenience use the space provided below to list this
information:

Model #: ____________________

Serial #: _________________________

Date of Purchase: _________________

Problem

Possible Cause

Solution

Fan does not turn when electricity is

connected

1. No electric power to heater

2. Blades of fan in contact with heater

housing

3. Fan blades bent

4. Fan motor defective

1. Check current at outlet. If voltage is correct,

inspect extension and power cords for cuts, frays
or breaks

2. Check housing for damage. Be sure there ar no

dents in the housing obstructing the fan

3. Straighten all fan blades

4. Replace Motor Assembly

Heater will not fire (ignite)

1. No spark at module

2. Incorrect spark gap

3. Corroded electrode

1. Inspect module wire. Re-attach, or tighten if loose.

Inspect Spark module, and replace if necessary.
Inspect all other electrical components

2. Set plug gap to 0.16” (4mm)

3. Replace spark plug (Multi-Bracket Assembly)

Heater stops running by itself

1. Temperature inside heater is too high,

causing thermal switch to shut down
operation

2. Damaged control valve

3. Dust or debris accumulated in heater

1. If heater input or output is restricted, the inside

temperature can become too hot. Keep the areas
in front and behind heater clear of obstructions

2. Replace control valve (Valve Assembly)

3. Clean inside of heater

Troubleshooting Guide

Propane

Forced Air Heaters

NEVER LEAVE HEATER UNATTENDED

WHILE BURNING, CONNECTED TO A

POWER SOURCE, OR WHILE

CONNECTED TO A FUEL SOURCE

Summary of Contents for MH-40-GFA

Page 1: ...5 Wiring Diagrams 6 Replacement Parts 6 7 Exploded Parts Drawing 7 Troubleshooting Guide Back Cover Warranty Back Cover GENERAL HAZARD WARNING Failure to comply with the precautions and instructions p...

Page 2: ...V 60 Hz 8 3 W C 0 8 17 6 25 x 8 6 x 15 5 MH 150V GFA 120 000 150 000 5 5 to 6 9 Lbs Hr 120V 60 Hz 8 W C 0 8 17 6 25 x 8 6 x 15 5 CAUTION Figure 1 Product Features Table 1 Specifications Specifications...

Page 3: ...is a direct fired forced air construction heater for either indoor or outdoor use It s intended use is primarily for the temporary heating of buildings under construction alteration or repair All of t...

Page 4: ...have a bleed off valve This valve should be inspected for leaks after each filling of the LP cylinder Turn the valve clockwise to close Fasten full Propane tank and connect proper fitting to LP cylin...

Page 5: ...IGN on Model MH 40 GFA 6 Keep the valve knob depressed for at least 30 seconds after lighting the burner After 30 seconds release valve knob 7 If burner does not stay lit repeat lighting procedure 8...

Page 6: ...0002 22 504 0002 22 504 0002 22 504 0003 1 8 Thermal Switch 22 603 0001 22 603 0001 22 603 0001 22 603 0001 1 9 Tubing Assembly 22 605 0001 22 605 0001 22 605 0005 22 605 0005 1 10 Nozzle 22 081 0007...

Page 7: ...3 22 507 0003 22 507 0003 1 21 Spark Module 22 604 0005 22 604 0005 22 604 0005 1 22 PCB Assembly 22 521 0001 22 521 0002 22 521 0002 22 521 0002 1 23 PCB Case 22 506 0001 22 506 0001 22 506 0001 22 5...

Page 8: ...BILITY AND FITNESS FOR A PARTICULAR APPLICA TION FURTHER Pinnacle Products International Inc SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL INDIRECT PUNITIVE INCI D...

Page 9: ...a en el futuro ADVERTENCIA GENERAL DE PELIGRO Aseg rese de cumplir con las instrucciones y advertencias suministradas con este calentador o de lo contrario se puede sufrir la muerte lesiones corporale...

Page 10: ...inistrado con este calentador debe uti lizarse sin hacerle ninguna alteraci n Informaci n de Seguridad General Indica una situaci n de peligro inmi nente que de no evitarse CAUSARA la muerte o una les...

Page 11: ...ra debe estar protegido contra el tr fico materiales de construcci n y el contacto con superfi cies calientes tanto durante el uso como durante el almace namiento IMPORTANTE Lea detenida y completamen...

Page 12: ...la del tanque de gas a la posici n OFF apagado Las v lvulas de tanque de propano equipadas con un acceso rio de estilo antiguo tienen ROSCAS DE MANO IZQUIERDA Gire el accesorio HACIA LA DERECHA para a...

Page 13: ...INSTRUCCIONES DE APAGADO Para apagar el calentador 1 Gire la perilla de la v lvula de gas hacia la derecha a la posi ci n OFF apagado 2 Gire hacia la derecha la v lvula del tanque de propano para cerr...

Page 14: ...A E E V L A V L O R T N O C E L P U O C O M R E T O L L E Figura 3 Modelos de Chispa Continua Fusible M dulo de Chispa C rdon de Alimentaci n Negro Motor Azul Encendedor Condensador Interruptor T rmi...

Page 15: ...taci n para ver si est cortado o est roto 2 Aseg rese que el alojamiento no est da ado Aseg rese que el ventilador no est obstruido 3 Enderece el aspa s para que quede como las otras 4 Reemplace el mo...

Page 16: ...de Construcci n a Propano Calentador para Uso en Tareas de Construcci n a Propano NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS STE EST ENCENDIDO CONEC TADO A UNA FUENTE DE ALIMENTACI N O MIENTRAS ES...

Page 17: ...0004 22 101 0004 18 Perno redondo 22 503 0002 22 503 0002 22 503 0003 22 503 0003 19 Conjunto de la v lvula 22 011 0005 22 011 0017 22 011 0018 22 011 0008 20 Conector de entrada 22 507 0003 22 507 00...

Page 18: ...deter mina que el art culo est en condici n normal de fun cionamiento o no defectuoso el art culo ser devuelto con flete por pagar Esta Garant a limitada sustituye toda otra garant a expresa Pinnacle...

Page 19: ...ra ner la mort des blessures graves des pertes ou des dommages mat riels suite aux risques d incendie d explosion de br lures d asphyxie d empoisonnement au monoxyde de carbone et ou de d charge lectr...

Page 20: ...tre utilis s sans tre modifi s Informations g n rales sur la s curit Indique un danger imminent qui s il n est pas vit ENTRA NERA la mort ou des blessures graves Indique un danger potentiel qui s il n...

Page 21: ...ffets nocifs sur la reproduction N est pas con u pour un usage r siden tiel ou dans un v hicule de plaisance L ensemble des tuyaux doit tre prot g contre le trafic les mat riaux de construction et un...

Page 22: ...gaz propane local Certains r servoirs de propane poss dent un robinet de purge Ce robinet doit tre inspect pour y d tecter des fuites apr s chaque remplissage du r servoir Tourner le robinet dans le...

Page 23: ...ns le sens horaire la position d arr t OFF 2 FERMER l alimentation en gaz en tournant le robinet de r ser voir de propane dans le sens horaire 3 D brancher le cordon d alimentation V RIFICATION DE LA...

Page 24: ...Bleu Jaune Blanc Bleu Blanc Noir Blanc Noir Vert Terre enveloppe Noir Terre Jaune Robinet de commande Thermocouple Thermo rupteur Cordon d alimen tation Noir Moteur Bleu Allumeur Condensateur Thermo r...

Page 25: ...du radiateur 1 V rifier la tension vers la prise lectrique Si la tension est correcte v rifier le cordon d alimen tation et la rallonge pour y d tecter des coupures ou des brisures 2 S assurer que le...

Page 26: ...U IL EST BRANCH UNE SOURCE D ALIMENTATION 1 2 6 7 8 12 13 14 15 16 17 25 20 23 22 19 5 28 27 4 24 3 9 11 10 18 21 26 Figure 4 Illustration des pi ces d tach es pour radiateurs de construction au propa...

Page 27: ...18 0003 1 14 Ventilateur 22 514 0001 22 514 0001 22 514 0002 22 514 0002 1 15 Tampon amortisseur 22 509 0001 22 509 0001 22 509 0001 22 509 0001 1 16 Moteur 22 061 0015 22 061 0015 22 061 0016 22 061...

Page 28: ...acheteur Sur r ception de l article endommag Pinnacle Products International Inc examinera l article en question et d terminera s il est d fectueux Pinnacle Products International Inc r parera ou rem...