Model: MC-1-DE
Doc Ref. No:-m05dom102
Issue No:-00
User’s Manual
Page 38 of 76
Figure 24 Hyper Terminal Property configuration
.
4. Set the baud rate to 4800 and check for other parameters to be same as that of GPS TIME SYNC
UNIT MC-1-DE
5. After setting the parameters, reconnect the link by right click on Call\Call.
6. Now press ESC and Enter keys.
7. Once the connection is reestablished, the time data will again be displayed on the HyperTerminal.
8.2.2.1 Command: SPx [Parity Command]
Applicable Options: SP0 / SP1 / SP2 (Please refer ‘H’ Command menu for applicable meanings of
mentioned options)
The change of parity configuration can be done using this command. Different options for the parity
settings are as below:
NOTE: It is necessary to change the value Parity, if user changes the parity of GPS TIME SYNC
UNIT MC-1-DE serial terminal as per applicable value mentioned below:
SP0
: No Parity
8 data bits
SP1
: Odd Parity
8 data bits
SP2
: Even Parity
8 data bits
Same as SBxx command, the communication stops as soon as you finish the command and press
‘Enter’ once. This is because the protocol settings at GPS TIME SYNC UNIT MC-1-DE and Hyper-