PERFORMANCE TEST
CAUTION:
Each test must be performed within 3 – 5 seconds to
avoid coil from burning.
1. Terminal ‘S’
PULL-IN TEST
Connect test leads as shown in figure and check that pinion (over-
running clutch) move outward. If it does not, replace magnetic
switch.
NOTE:
Before testing, disconnect field coil lead (3) from ‘M’ terminal
(2).
HOLD-IN TEST
While connected as the above with pinion out, disconnect negative
lead from ‘M’ terminal (1) and check that pinion remains out. If not,
replace magnetic switch.
CRANKING SYSTEM
6G-11
SH410