Removal
Refer to REMOVAL and DISASSEMBLY in the previous section
COOLING UNIT (EVAPORATOR).
Inspection
1) Connect manifold gauge set (1) to expansion valve (2) and its
charging hose to refrigerant container (3).
2) Soak remote bulb of expansion valve in water contained in a
water pan (4).
3) Previously close both low and high pressure valves.
4) Open refrigerant container valve.
5) Open high pressure valve to adjust pressure to approx. 5 kg/
cm
2
.
6) Read the pressure indicated on low pressure gauge (5). At the
same item use a thermometer to measure water temperature.
7) Use the Chart as shown left to check whether above measure-
ments faIl within shaded acceptable range.
AIR CONDITIONING (OPTIONAL)
1B-31