76
DMX protocols
Imager 01 DMX-Gobo with moving-
mirror fitted
Start code = 0
DMX 1
DMX 2
Value
Percent
Function
1
0 - 208
208 - 217
218 - 227
228 - 237
238 - 247
248 - 255
0 - 81
81 - 85
85 - 87
89 - 93
93 - 97
97 - 100
Reset, Lamp On/Off
Reserved (no change)
Reset fixture
Reserved (no change)
Lamp power on
Reserved (no change)
Lamp power off: T >= for 5 seconds
If reset or power off are disabled,
confirm by setting DMX-channel 3 to
any value in the ranges 60-79 or 140-
159, and focus in near position.
(channel 5 or 6).
2
0 - 255
0 - 100
Intensity
Intensity 0
→
100%
3
0 - 79
80 - 159
160 - 255
0 - 31
31 - 62
63 - 100
Image Selection
Image, indexed rotation
Image, continuous rotation
Reserved (no change)
4
0 - 255
0 - 2
3 - 127
128 - 252
253 - 255
0 - 100
0
1 - 50
50 - 99
99 - 100
Image Rotation (select indexed
image rotation, on channel 3)
Coarse position index (MSB),
Min
→
Max
Rotation Velocity (select cont.
image rotation, on channel 3)
No rotation
CCW rotation, slow
→
fast
CW rotation, fast
→
slow
No rotation
5
0-255
0-100
Image Rotation, Fine Position
Fine position index (LSB), Min
→
Max
5
6
0-255
0-100
Focus
Infinity
→
near
6
7
0-255
0-100
Pan
Left
→
right (128 = neutral)
8
0-255
0-100
Pan fine (LSB)
Left
→
right
7
9
0-255
0-100
Tilt
Up
→
down (128 = neutral)
Summary of Contents for Imager Series
Page 1: ...Imager Series user manual mar tin ar chi tect u ra l ...
Page 5: ...5 SECTION 1 GETTING STARTED ...
Page 25: ...General operation 25 SECTION 2 STAND ALONE OPERATION ...
Page 37: ...Synchronous triggering during Stand Alone operation 37 SECTION 3 DMX CONTROL ...
Page 43: ...DMX Controller operation 43 SECTION 4 OPTICS AND PROJECTION ACCESSORIES ...
Page 54: ...54 Moving mirror ...
Page 55: ...Moving mirror 55 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Page 65: ...Troubleshooting 65 SECTION 6 REFERENCE ...
Page 81: ...Specifications Imager 81 ...
Page 82: ......
Page 83: ......