18
Installation
3 If you are not using the infrared remote control and receiver, ensure that the
the link is terminated with an RJ-45 termination plug (one is supplied and
pre-installed in the J-Box) into the DMX data output of the last J-Box.
Warning
If you are using Stand-Alone programs (see “Stand-Alone
programming overview” on page 26) on multiple fixtures on a
data link and you experience random “flicker” or other
unexplained control problems, insert a female termination plug
(P/N 91613018) into the last fixture on the data link.
Replacing the Imager J-Box cover
1 Four holes, for cabling, are semi-
stamped in the side of the J-Box
cover. If these are needed, take a
pair of needle-nose pliers and break
the metal stamps out of the cover.
Place the supplied cable glands
over the cables and push them into
the holes in the junction-box cover.
2 Before closing the J-Box ensure that the power and data network cables
(“Data linking multiple fixtures” on page 16) are attached to the terminals.
3 Push the Imager J-Box cover into place.
4 Using the 2.5 mm Allen wrench, tighten the three Allen screws that hold the
cover in position.
Adjusting the projection angle
You can adjust the angle of the luminaire by making adjustments at the
joints. To adjust a joint, use the 6 mm Allen wrench to loosen the joints on
either side of the fixture. Adjust to the desired angle and re-tighten.
Summary of Contents for Imager Series
Page 1: ...Imager Series user manual mar tin ar chi tect u ra l ...
Page 5: ...5 SECTION 1 GETTING STARTED ...
Page 25: ...General operation 25 SECTION 2 STAND ALONE OPERATION ...
Page 37: ...Synchronous triggering during Stand Alone operation 37 SECTION 3 DMX CONTROL ...
Page 43: ...DMX Controller operation 43 SECTION 4 OPTICS AND PROJECTION ACCESSORIES ...
Page 54: ...54 Moving mirror ...
Page 55: ...Moving mirror 55 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Page 65: ...Troubleshooting 65 SECTION 6 REFERENCE ...
Page 81: ...Specifications Imager 81 ...
Page 82: ......
Page 83: ......