Service
59
• The Software Uploader program, version 5.3 or later - supplied with the
Martin MP-2, LightJockey, or available for download from the support pages
for these products in the User Support Area of the Martin web site.
Important
In DMX or SA-mode (Stand Alone mode) the data link must be
terminated.
In IR-mode press the ID button for approximately 5 sec. then the
fixtures will go into DMX-mode and the fixtures can be
uploaded. Remove the IR-Remote receiver and terminate the
link. After fixture power off the fixtures will be in IR-mode again.
For guidance on preparing a LightJockey, MP-2 or Software Uploader refer
to the user documentation and online help for these products. Follow these
instructions before proceeding to the next section.
Updating fixture firmware with the MP-2 Uploader
1 Connect a prepared MP-2 Uploader to the DMX link on the Imager. Apply
power to the fixtures and the MP-2. Wait a few moments for the fixtures to
reset.
2 Select
Read Memory Card
from the MP-2 main menu.
3 Use the buttons on the right to scroll through the card slots. Select the slot
that holds the desired version of the Imager firmware.
4 Select
Update Software
. Select
Yes
to confirm.
5 Select
Update
in
DMX
mode
to start the upload. The MP-2 initializes all
connected Imagers.
6 After a successful upload the fixtures reset with the new software. If an error
occurs and the fixtures do not reset, data was interrupted or corrupted
during transmission. Perform a boot mode upload as described in the
following section.
Boot sector upload
If the normal upload procedure does not work, or if the software update
notes call for a boot sector update. Boot sector update mode needs to be
set either in the control menu, or by moving a jumper on the PCB in the
Imager.
Performing a boot sector update by moving a PCB
jumper
1 Make sure the Imager is isolated from AC power.
Summary of Contents for Imager Series
Page 1: ...Imager Series user manual mar tin ar chi tect u ra l ...
Page 5: ...5 SECTION 1 GETTING STARTED ...
Page 25: ...General operation 25 SECTION 2 STAND ALONE OPERATION ...
Page 37: ...Synchronous triggering during Stand Alone operation 37 SECTION 3 DMX CONTROL ...
Page 43: ...DMX Controller operation 43 SECTION 4 OPTICS AND PROJECTION ACCESSORIES ...
Page 54: ...54 Moving mirror ...
Page 55: ...Moving mirror 55 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Page 65: ...Troubleshooting 65 SECTION 6 REFERENCE ...
Page 81: ...Specifications Imager 81 ...
Page 82: ......
Page 83: ......