General operation
23
Lamp Temperature fan regulation
Allows the lamp fan in a Imager to be automatically adjusted based on the
temperature. This is on by default.
Gobo Temperature fan regulation
Allows the gobo fan in a Imager to be automatically adjusted based on the
temperature. This is on by default.
Temperature warnings enabled
Enables temperature warnings to appear in the display and shut down the
lamp.
Lamp hour warning
Using this menu you can enable or disable lamp life warnings and set the
number of hours of expected life that apply to the lamp type installed. A
counter operates that can be read and reset in the
I n f
menu. When the
resettable lamp hour counter reaches:
• 100 hours less than the predefined lamp hour warning level, the display will
start blinking ‘Lhu’ in the display. At this point you should change the lamp to
avoid the risk of lamp explosion.
• The predefined lamp hour warning level, the lamp shuts off and can not be
turned on again before the counter is reset, or the predefined lamp hour
warning level has been redefined.
This is option is off by default. We recommend that you activate the Lamp
Hour Warning function on the Imager and that you set the expected number
of hours of life the lamp has. Remember to also reset the lamp hour counter
using the Information menu.
Note that because the display is limited to 3 digits, and many lamps have a
life that is measured in thousands of hours, the counters are set to 1/100ths
of their actual value. For example for a lamp that has a life of 3000 hours,
the lamp hour warning level would be set to 30.
Restore factory defaults
Restores factory default settings in the Personality menu.
Reset all counters
Resets all resettable counters (these are found under the Information
menu).
Summary of Contents for Imager Series
Page 1: ...Imager Series user manual mar tin ar chi tect u ra l ...
Page 5: ...5 SECTION 1 GETTING STARTED ...
Page 25: ...General operation 25 SECTION 2 STAND ALONE OPERATION ...
Page 37: ...Synchronous triggering during Stand Alone operation 37 SECTION 3 DMX CONTROL ...
Page 43: ...DMX Controller operation 43 SECTION 4 OPTICS AND PROJECTION ACCESSORIES ...
Page 54: ...54 Moving mirror ...
Page 55: ...Moving mirror 55 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Page 65: ...Troubleshooting 65 SECTION 6 REFERENCE ...
Page 81: ...Specifications Imager 81 ...
Page 82: ......
Page 83: ......