50
Lens options
Lens options
The following lenses are available for the Imager luminaire:
• 23° lens (fitted as standard)
• 15° lens (a screw on attachment) - P/N 91611074
• 32° lens (a screw on attachment) - P/N 91611075
Changing the lens
To change the lens:
1 Disconnect the fixture from AC power and allow it to cool for 30 minutes.
2 Remove the cover of the fixture using a 2.5 mm Allen wrench.
3 Rotate the spindle to move the standard lens as far away from the lamp as
possible.
4 Slide the optional lens in under the standard lens, and screw it to the thread
on the standard lens.