Service
29
S
ERVICE
7
This section describes service procedures that can be performed by the user. Refer
all service not described here to a qualified Martin technician.
Warning!
Disconnect the fixture from power before removing the fixture
housing.
L A M P R E P L A C E M E N T
The FiberSource CMY150 uses one of the following discharge lamps.
Installing any other lamp may damage the fixture.
Warning!
Allow the lamp to cool for 15 minutes before removing the lamp
cover.
Lamp replacement requires a 5 mm Allen wrench and a Philips screw driver.
To replace the lamp:
1 Disconnect the fixture from power and allow it to cool.
2 Remove the fixture housing.
Lamp
Efficiency
Color Temp.
Average Life
Philips MasterColor CDM-SA/R
150W
33 Lm/W
4200 K
6000 hr.
Osram HQI-R 150W
(can only be operated horizontally)
35 Lm/W
4200 K
6000 hr.
Table 5: Lamp specifications