18
P3
Start Disable
P4
Sensor 1
P5
Sensor 2
P4 Sensor #1 and P5 Sensor #2
P3 Starter Disable (Ground when Armed)
Plug-In Ports
2-Stage Sensor:
Allows easy connection with quick disconnect ability for
other optional devices.
1. Red: +12 Volt Constant Input
2. Black: Main Sensor Ground
3. Blue: Instant Trigger (-) Input
4. Green: Warn Away (-) Input
Starter Disable Wiring Using ALA-RPS Relay Pack
Using the wiring information and diagram below, connect the optional starter disable relay as follows:
A. Locate the “Start Only Wire” coming from the ignition key switch and cut it.
B. Connect the ends of the cut start wire to the black wires coming from the ALA-RPS relay pack.
C. Plug in the orange 2-pin plug into the orange socket located on the alarm module.
To test the starter disable system refer to the starter disable testing procedures located in the testing section of
this manual.
87
87a
86
85
30
"ACC"
"START"
"OFF"
"ON"
Cut
Black
Starter
ALA-RPS
Relay Pack
Red Wire
(Ign. Sw12VDC)
Black Wire
(Ground when Armed Alarm Output)
Black
Violet Wire
6-Pin
White Connector