Advanced Configuration
Advanced Configuration changes some complex parameters within the device and should only be
performed by an advanced user. Typically, advanced configuration is only done at installation and
should not need to be done while at sea.
Figure 131
– J2K100 Advanced Configuration Screen
6.17.1.1
Data Damping
In order to smooth the results viewed on a display, you may individually change the data damping
period that the J2K100 uses when sending fuel rate and tachometer (engine RPM) information. The
default is to use no damping (0.0 seconds). You may program the damping from none up to 5
seconds.
6.17.1.2
Device Instance
The Device Instance will be used to identify the J2K100 module on the network. If a GenSet is
connected to the J1939 network, and the AC parameters passed through the J2K100 interface, the