6 Device Configuration
The “Device Configuration…” menu enables you to configure certain types of devices on the NMEA
2000
®
network. Devices that may be configured using the DSM150 include the following:
Airmar Depth, Speed, and Temperature Transducers (DST800, DT800, P39, P79, B122,
ST850, ST800, HT200)
– Reset trip log, set depth offset, speed calibration, and temperature
offset (if applicable)
Bennett EP-30
– Calibrate trim tabs.
Maretron Alternating Current Monitor (ACM100)
– Set circuit type, device type, instance
number, and label. Reset the total energy recorded.
Maretron Annunciator (ALM100)
– Set the Data Instance Number, and the Label. Test the
alarm.
Maretron Direct Current Monitor (DCM100)
– Set the Battery Type, and calibrate the current
sensor zero offset.
Maretron Direct Current Relay Module (DCR100)
– Set the operating mode of each channel,
lock switches, set power up state, and control state of switches
Maretron Monochrome Display (DSM200)
– allows configuration of other DSM200s on the
network
Maretron Color Display (DSM150, DSM250)
– allows configuration of other DSM150s and
DSM250s on network
Maretron Depth/Speed/Temp. Transducer (DST100)
– set transducer offset, zero trip distance
log
Maretron Depth/Speed/Temp. Transducer (DST110)
– Reset trip log, set depth offset, speed
calibration, and temperature offset
Maretron Engine Monitoring System (EMS100)
– set the gauge types for Boost Pressure, Drive
Trim, Oil Pressure and Water Temperature. Preset the Engine Hours
Maretron Fuel Flow Monitor (FFM100)
– Set operating mode, channel direction, K-factor,
temperature coefficient
Maretron Fluid Pressure Monitor (FPM100)
– Set the operating mode of each channel, perform
tank levels calibration, set pressure sender characteristics
Maretron GPS Antenna/Receiver (GPS100)
– enable and disable WAAS functionality, set the
GPS mode, program the elevation, PDOP and SNR masks, set the antenna altitude, force a
cold start, enable/disable individual PGN transmission, and reset the unit back to its factory
defaults.
Maretron GPS Antenna/Receiver (GPS200)
– enable and disable WAAS functionality, force a
cold start, enable/disable individual PGN transmission, and reset the unit back to its factory
defaults.
Maretron Internet Protocol Gateway(IPG100)
– set IP connection parameters, set N2KServer
password, view N2KServer information, and reset the unit back to its factory defaults.
Maretron J1939 to NMEA 2000 Gateway (J2K100)
– set J1939 node address, set NMEA 2000
®
engine/transmission instance, enable pass-through of J1939 diagnostic messages, and
enable/disable individual NMEA 2000
®
PGN transmissions.
Maretron Network Bus Extender (NBE100)
– Set device label
Maretron Rudder Angle Adapter (RAA100)
– Set rudder number, operating mode, and calibrate
rudder position.