Figure 230
– Installation Offset Abort Confirmation Screen
6.31.5
Wind Data Damping Period
The WSO100 comes from the factory preset with a damping period of 1.5 seconds, which should be
appropriate for most applications. However, you may use the DSM150 to tune the damping period to
anywhere between 0.1 seconds and 5.0 seconds if you desire. To do this, use the Scroll Up (
) or
Scroll Down (
) keys to move the highlighted cursor to the “Wind Data Damping Period:” menu
item, then press the Enter key (
) to move the highlight to the numerical value on the right. This is
shown in Figure 231 below. Use the Increase and Decrease keys to adjust the damping period to the
desired value, and then press the Enter key (
) to accept the value and store it within the WSO100.
Figure 231
– Setting the Wind Data Damping Period
6.31.6
Barometric Pressure
The WSO100 has an internal barometer, which is pre-calibrated before leaving the factory. If the unit
requires re-calibrating, then this field allows the entry of the actual pressure. This may be necessary if
the vessel is on a lake with an altitude other than sea level, and the user wishes to normalize the
barometric pressure to sea level.