DSM150
User’s Manual
Page 142
Revision 1.4.18
standard values of resistances for rudder angle senders and for rudders with maximum port and
starboard angles of anything other than 45°.
To perform custom calibration of the rudder angle sender, use the Scroll Up (
) or Scroll Down (
) keys to move the h
ighlighted cursor over the “Custom Calibration…” menu item. Then, press the
Enter key (
) to confirm your selection and begin the calibration process. Figure 145 shows the
DSM150 with the Custom Rudder Calibration menu item highlighted.
Figure 145
– RAA100 Custom Rudder Angle Calibration
The first step in the custom rudder angle sender calibration process is to turn the wheel hard over to
starboard, and to measure the angle or the rudder (angle from center) with a protractor or other
instrument. Use the Increase and Decrease keys until the highlighted rudder angle value is at the
measured value, and then press Enter to accept the value and store it within the RAA100. Figure 146
shows a screenshot of the starboard rudder calibration screen. You may also press the Abort Key (
) to end the calibration process.
Figure 146
– RAA100 Starboard Rudder Angle Calibration
Summary of Contents for DSM150
Page 16: ......
Page 163: ...Revision 1 4 18 Page 147 Figure 153 RAA100 Setting the to Sender Gauge Resistance...
Page 233: ...Revision 1 4 18 Page 217 Figure 254 Favorite Screen Showing Highlighted Switch Breaker...
Page 263: ...Revision 1 4 18 Page 247 Figure 288 Restore Factory Defaults Confirmation...