Revision 1.4.18
Page 189
6.28.3
Channel Configuration
Individual channels may be configured by using the
Scroll Up
and
Scroll Down
buttons to highlight
the channel, and then pressing the
Enter
key. The following screen will be displayed.
Figure 217
– TMP100 Channel Configuration Screen
6.28.3.1
Instance
The Data Instance of the Temperature (as sent in PGNs 130311, 130312, and 130823) is set in this
field. Use the
Increase
and
Decrease
buttons to select the correct instance number, and the press
the
Enter
button to store it.
6.28.3.2
Source
In the NMEA2000
®
PGNs, each temperature is associated with a source type. Possible values are:
Bait Well Temperature
Engine Room Temperature
Exhaust Gas Temperature
Freezer Temperature
Heating System Temperature
Inside Temperature
Live Well Temperature
Main Cabin Temperature
Outside Temperature
Refrigeration Temperature
Sea Temperature
User Defined Temperature #129...#144
– Use this when none of the above options are suitable.
Use the
Scroll Up
and
Scroll Down
buttons to select the correct source, and the press the
Enter
button to store it.
6.28.3.3
Label
A label may be assigned to each channel of the TMP100 as an aid to identifying the temperature that
is being displayed. Typically this label will describe the function or location of the temperature sensor.