Revision 1.4.18
Page 225
Figure 260
– Low Alert Parameters
A low alert is triggered (i.e. becomes an active alert) once an input signal has dropped below the
Low
Alert Set Point
and the
Set Delay
time has elapsed. If the S
et Delay
is set to zero, then the alert is
immediately triggered once the input signal drops below the
Low Alert Set Point
. The
Set Delay
is
used to reduce false or spurious alerts. As an example, setting the
Set Delay
to 5 seconds will
eliminate any temporary transitions of the input signal above the
Low Alert Set Point
lasting less than
5 seconds from triggering an alert. Once the alert is triggered, it becomes an active alert. An alert
remains active until:
The input signals rises above the
Low Alert Clear Point
and the
Clear Delay
time has elapsed.
If the
Clear Delay
is set to zero, then the alert immediately becomes inactive once the input
signal falls below the
Low Alert Clear Point
. The
Clear Delay
is used to reduce false or
spurious alerts.
The user accepts the alert (as shown in the example above).