then the user can create a filter using 4 standard independent IIR filter Cell (with each IIR cell is
possible create a 2
nd
order filter, is possible change the Q, Frequency and the filter enable) in
cascade mode
if the
FIR
is selected then, the system show the following control
type: High Pass type: Band Pass
type: Low Pass type: imported from external
Is possible to bypass the FIR using the relative check-box “Bypass”, is possible to save the filter to
a file.txt in order to reload it (as External filter) or use it for other applications, is possible to see the
Amplitude and Phase of the FIR loaded (the page to “view only” the plot is the same page used to
import an external FIR).
The FIR Filter type are HP, LP, BP (are internally calculate and dependent from the option taps,
attenuation, window type and cut-off frequency) and External Filter (the user can import a file with
the coefficient of the FIR already calculate with other tools, please see the appendix “Import FIR
Filter” to understand how it is work)
2nd ord
2nd ord
2nd ord
2nd ord
Signal
i
Signal Out
Summary of Contents for LPP-480F
Page 1: ...User Manual LPP 480F...
Page 49: ......