80
4. Neatly route the two conductor cables of the
alarm box to the low pressure switch and attach to
the terminal of the pressure switch (refer to the
figure below).
NOTE: Gray cable connector may be shortened.
5. Plug alarm box transformer into 120 VAC, 60 Hz
outlet. The CO
2
alarm “Low Pressure” light should
illuminate.
6. Turn ON CO
2
at the CO
2
tank. Adjust pressure to
40 psig. Slide the switch to “Normal Operation”
position; beeper will sound. Press switch to
“Test/Reset” position; light will extinguish and
beeper will stop.
7. Installation is complete.
CO
2
Supply
CO
2
Low
Pressure Switch
Assembly
1/4" x 1/4" x 1/4"
Stainless Steel Tee
Low CO
2
Alarm Box
Primary Regulator
set at 40 psig
120 VAC
Outlet
Transformer