43
INSTALLING THE CONDUIT KIT
Connections Preview
Review the three illustrations under “Circuit Diagrams”
in the Diagrams section to determine which best
illustrates your particular installation. Consider the
following while examining the drawings:
Beer conduits have been designed to achieve the
proper cooling of each encased beer line. In order to
function properly, you must follow these guidelines:
Up to eight line conduit:
•
six beer maximum, one glycol circuit (two lines)
Ten and over line conduit:
•
two glycol circuits (four lines)
To ensure colder dispensing temperatures, glycol
should flow directly to the dispensing towers before
returning to the remote Glycol Chiller Unit. After
examining the drawings determine the desired glycol
circuit to be achieved and illustrate on paper for
referral. Do the same for the assignment of the beer
supply lines.
STH13_Tech.book Page 43 Wednesday, September 15, 2010 3:20 PM