28
Location Requirements
Select a location for the refrigeration unit that meets
the requirements of the building plans, local codes,
and personnel. The unit must be positioned for free
airflow as well as for future service. The following
requirements must be met:
•
Beverage quality CO
2
gas (bulk or bottled supply)
with a minimum 3/8" (.96 cm) line
NOTE: Refer to serial plate on front of refrigeration
unit for voltage and amperage specifications. Make all
electrical connections at the junction box located at the
top rear of unit. Optional equipment may require
additional power supplies.
!
Warning
Carbon Dioxide (CO
2
) displaces oxygen.
Exposure to a high concentration of CO
2
gas
causes tremors, which are followed rapidly by
loss of consciousness and suffocation. If a CO
2
gas leak is suspected, particularly in a small area,
immediately ventilate the area before repairing
the leak. CO
2
lines and pumps must not be
installed in an enclosed space. An enclosed
space can be a cooler or small room or closet.
This may include convenience stores with glass
door self serve coolers. If you suspect CO
2
may
build up in an area, venting of the BIB pumps
and/or CO
2
monitors must be utilized.
STH13_Tech.book Page 28 Wednesday, September 15, 2010 3:20 PM