113
There are 4 programming modes:
1. View conductivity
2. Add additional (third or fourth) circulation pumps
3. Set water/glycol temperature
4. Temporarily cancel display of error codes
SER Switch
•
LED is energized when LON communication
network is connected.
•
LED is de-energized when LON communication
network is disconnected.
PGM Switch
•
Used to enter and exit programming modes. To
enter, press and hold switch for 3 seconds.
PROGRAM MODE 1
•
0001
will display indicating Mode 1
•
Wait 3 seconds
C000
will display
•
Press and hold CIRC A switch — Display will
indicate water/glycol bath probe conductivity:
-
CL0
— Water/Glycol mix too low
-
CL1
— Water/Glycol mix high enough
Press and hold PGM switch for 3 seconds to exit
program mode
.
PROGRAM MODE 2
Add circulation pumps C & D.
•
Press PGM button for 3 seconds — Display shows
0001
.
•
Press PGM button — Display shows
0002
program mode 2.
•
Wait 3 seconds — Display shows
-002
= Factory
default setting.
-
Pressing CIRC A button energizes/
de-energizes pump A
-
Pressing CIRC B button energizes/
de-energizes pump B
STH13_Tech.book Page 113 Wednesday, September 15, 2010 3:20 PM