Part Number Preliminary 6/11
237
Diagnostics
SYMPTOMS
Bin Switch Fails Open
•
The ice machine will not start an ice making cycle
and the display indicates “Curtain Open”.
•
The ice machine will run in the clean cycle.
Bin Switch Fails Closed
•
When running a “Long Harvest” alert is displayed
and safety limit 2 indicated.
•
May be off on a safety limit 2.
•
The harvest cycle continues after ice opens and
closes the ice damper (harvest cycle is 3.5
minutes for single evaporators and 7 minutes for
multiple evaporator models).
DIAGNOSTICS
1. Verify bin switch, damper and damper magnet are
in place.
•
Press the Menu button.
•
Scroll down to Service and press right arrow.
•
Scroll down to Diagnostics and press right arrow
•
Scroll down to Inputs and press right arrow to
display curtain switch readings (Curt SW1, Curt
SW2, etc).
2. Open and close the ice damper(s) repeatedly
while observing the display and control board
lights.
A. Curtain switch cycles open/closed and
control board light energizes/de-energizes -
Bin switch is operating normally
B. Curtain switch remains closed and control
board light remains on - Replace bin switch
C. Curtain switch remains open and control
board light remains off - Go to next step
Summary of Contents for ICVD3095
Page 2: ......
Page 12: ...12 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 25: ...Part Number Preliminary 6 11 25 This Page Intentionally Left Blank ...
Page 26: ...26 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 36: ...36 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 72: ...72 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 101: ...Part Number Preliminary 6 11 101 This Page Intentionally Left Blank ...
Page 132: ...132 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 137: ...Part Number Preliminary 6 11 137 This Page Intentionally Left Blank ...
Page 138: ...138 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 187: ...Part Number Preliminary 6 11 187 This Page Intentionally Left Blank ...
Page 188: ...188 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 225: ...Part Number Preliminary 6 11 225 This Page Intentionally Left Blank ...
Page 226: ...226 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 262: ...262 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 283: ...Part Number Preliminary 6 11 283 ACCESS REMOTE RECOVERY EVACUATION CONNECTIONS ...
Page 291: ...Part Number Preliminary 6 11 291 This Page Intentionally Left Blank ...
Page 298: ...298 Part Number Preliminary 6 11 USING PINCH OFF TOOL ...
Page 303: ...Part Number Preliminary 6 11 303 This Page Intentionally Left Blank ...
Page 304: ...304 Part Number Preliminary 6 11 ...
Page 305: ...Part Number Preliminary 6 11 305 This Page Intentionally Left Blank ...
Page 306: ...306 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 337: ...Part Number Preliminary 6 11 337 I0500 Remote Air cooled 1Ph ...
Page 339: ...Part Number Preliminary 6 11 339 I0600 I0850 I1000 Remote Condenser Air cooled 1 3 Ph ...
Page 341: ...Part Number Preliminary 6 11 341 IB0690C IB0890C IB1090C QuietQube Remote Air cooled 1 3 Ph ...
Page 342: ...342 Part Number Preliminary 6 11 I1400 I1800 Self Contained Air Water cooled 1 3 Ph ...
Page 343: ...Part Number Preliminary 6 11 343 I1400 I1800 Remote Air cooled 1 3 Ph ...
Page 349: ......