Part Number Preliminary 6/11
39
QUIETQUBE® REMOTE CONDENSING UNIT
QuietQube®
Ice Machine
Remote Single
Circuit
Condenser
Line Set*
I0670C
IB0670C
ICVD0695
RC-26
RC-36
RC-56
I0870C
IB0870C
ICVD0895
I1070C
ICVD1095
IB1090C
ICVD1195
I1470C
ICVD1495
RC-25
RC-35
RC-55
I1870C
ICVD1895
I2170C
ICVD2095
RC-28
RC-38
RC-58
I3070C
ICVD3095
RC-29
RC-39
RC-59
*Line Set
Suction
Line
Liquid
Line
Minimum
Insulation
Thickness
RC 26/36/56
5/8 inch
(16 mm)
3/8 inch
(10 mm)
1/2" (13mm)
Suction Line
1/4" (7mm)
Liquid Line
RC 25/35/55
3/4 inch
(19 mm)
1/2 inch
(13 mm)
1/2"(13mm)
Suction Line
1/4" (7mm)
Liquid Line
RC 28/38/58
3/4 inch
(19 mm)
5/8 inch
(16 mm)
1/2"(13mm)
Suction Line
1/4" (7mm)
Liquid Line
RC 29/39/59
Two Lines
3/4 inch
(19 mm)
One Line
5/8 inch
(16 mm)
3/4"(19mm)
Suction Line
1/4" (7mm)
Liquid Line
Summary of Contents for ICVD3095
Page 2: ......
Page 12: ...12 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 25: ...Part Number Preliminary 6 11 25 This Page Intentionally Left Blank ...
Page 26: ...26 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 36: ...36 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 72: ...72 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 101: ...Part Number Preliminary 6 11 101 This Page Intentionally Left Blank ...
Page 132: ...132 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 137: ...Part Number Preliminary 6 11 137 This Page Intentionally Left Blank ...
Page 138: ...138 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 187: ...Part Number Preliminary 6 11 187 This Page Intentionally Left Blank ...
Page 188: ...188 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 225: ...Part Number Preliminary 6 11 225 This Page Intentionally Left Blank ...
Page 226: ...226 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 262: ...262 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 283: ...Part Number Preliminary 6 11 283 ACCESS REMOTE RECOVERY EVACUATION CONNECTIONS ...
Page 291: ...Part Number Preliminary 6 11 291 This Page Intentionally Left Blank ...
Page 298: ...298 Part Number Preliminary 6 11 USING PINCH OFF TOOL ...
Page 303: ...Part Number Preliminary 6 11 303 This Page Intentionally Left Blank ...
Page 304: ...304 Part Number Preliminary 6 11 ...
Page 305: ...Part Number Preliminary 6 11 305 This Page Intentionally Left Blank ...
Page 306: ...306 Part Number Preliminary 6 11 This Page Intentionally Left Blank ...
Page 337: ...Part Number Preliminary 6 11 337 I0500 Remote Air cooled 1Ph ...
Page 339: ...Part Number Preliminary 6 11 339 I0600 I0850 I1000 Remote Condenser Air cooled 1 3 Ph ...
Page 341: ...Part Number Preliminary 6 11 341 IB0690C IB0890C IB1090C QuietQube Remote Air cooled 1 3 Ph ...
Page 342: ...342 Part Number Preliminary 6 11 I1400 I1800 Self Contained Air Water cooled 1 3 Ph ...
Page 343: ...Part Number Preliminary 6 11 343 I1400 I1800 Remote Air cooled 1 3 Ph ...
Page 349: ......