background image

 

Operation 

Manual 

Romar Pasta Cooker

630-ROM4

 

Product Identification 

 

 

The 630-ROM4 Romar Pasta Cooker automates fresh 
cooking and dispensing of individual servings of dry 
pasta. At the touch of a button, a pasta hopper 
dispenses an individual portion of dry pasta, then uses 
pressure, water and steam to rapidly cook the pasta to 
perfection every time in about 3 minutes per serving. 

 

TABLE OF CONTENTS 

LIMITED WARRANTY 

This product is warranted to be free from defects in material and/or 
workmanship for a period of one (1) year from date of original 
installation, not to exceed 30 months from date of shipment from 
our factory. Any component which proves to be faulty in material 
and/or workmanship will be replaced or repaired (at the option of 
Prince Castle, Inc.) without cost to the customer for parts or labor. 
This warranty covers on location service (i.e., trip charges and/or 
mileage). Travel mileage is limited to 100 miles (200 kilometers) 
round trip (one trip warranty) from an authorized service agency or 
its sub-service agency. 
This warranty is subject to the following exceptions/conditions: 

• 
• 

• 

• 
• 
• 
• 
• 
• 
• 
• 

Use of any non-genuine Prince Castle parts voids this warranty. 
All labor shall be performed during regular work hours. 
Overtime premium will be charged to the buyer. 
Damage caused by carelessness, neglect, and/or abuse (e.g., 
dropping, tampering or altering parts, equipment damaged in 
shipment, by fire, flood or an act of God) is not covered under 
this warranty.

 

SPECIFICATIONS 

Power Voltage.........................................................................240 VAC 
Power Amps........................................................................... 27 Amps 
Phase................................................................................................... 3 
Frequency ............................................................................... 50/60 Hz 
Boiler Controller Power ............................................................24VAC 
Control Power...........................................................................24 VAC 
Max Pressure ............................................................................100 PSI 
Working Pressure...................................................................... 80 PSI

 

 

 

 

 

355 East Kehoe Blvd. • Carol Stream, IL 60118 

Phone: 630-462-8800 • Toll Free: 1-800-PCASTLE 

Fax: 630-462-1460 • www.PrinceCastle.com

 

P r o d u c t   I d e n t i f i c a t i o n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
S a f e t y   I n f o r m a t i o n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
I m p o r t a n t ! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
I n s t a l l a t i o n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
G e n e r a l   P r e p a r a t i o n   &   O p e r a t i o n . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
C o o k i n g   P a s t a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
P e r i o d i c   M a i n t e n a n c e   &   C l e a n i n g . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

 

 

630-500 

 

Printed in USA  0404 © 2004 

Summary of Contents for 630-ROM4

Page 1: ...and or mileage Travel mileage is limited to 100 miles 200 kilometers round trip one trip warranty from an authorized service agency or its sub service agency This warranty is subject to the following exceptions conditions Use of any non genuine Prince Castle parts voids this warranty All labor shall be performed during regular work hours Overtime premium will be charged to the buyer Damage caused ...

Page 2: ...pable of withstanding 340 lbs weight of unit This unit is completely pre wired and thoroughly tested prior to shipment All wiring and hookups shall be done without opening the unit Place unit on the counter The counter must be designed to fit the size and support the weight of the unit The unit must be level to insure proper function To level the unit use only the adjustable leveling feet no shims...

Page 3: ...s indicated in the Pre Installation requirements the user must provide a circuit breaker between the main power source and the unit Refer to nameplate for rating The unit is wired and tested by the factory to operate only with a single phase power configuration with one ground for main load and circuit control To avoid severe electrical shock provide grounding in accordance with N E C requirements...

Page 4: ...g cut pasta Use only pasta recommended by Prince Castle Using other types of pasta or food may cause severe damage and void all warranties and maintenance contracts 3 4 A Remove the loading box cover allowing pasta to fall into the hopper B Place loading box cover firmly on top of loading box The long cut Pasta Dispenser is now ready for use It is recommended that you keep the hopper supplied with...

Page 5: ...thoroughly before first time use Wash trays and all strainers frequently to prevent starch accumulation Switching the Unit On 1 2 Ensure that all the previous steps were executed properly before proceeding A Visually and manually check that the Blow Down valve is closed B Check that water supply line is fully opened Verify that the on off switch on the back of the unit is in ON position When unit ...

Page 6: ...as filled the Sight Glass halfway WARNING EXPLOSION DAMAGE INJURY HAZZARD The Sight Glass indicator should NEVER rise above the full position If so immediately shut down the unit and call for repair WARNING EXPLOSION DAMAGE INJURY HAZZARD Do NOT turn either of the two red handled Sigh Glass turn valves These are used by authorized service personnel ONLY Hold the blue I O button for approx 3 secs T...

Page 7: ...omplete Daily Blow Down Procedure IMPORTANT It is extremely important to fully understand and perform these maintenance procedures This procedure should be performed with caution preferably at the end of the workday For the first few days only TWO blow downs per day are recommended to clean the inside of the boiler A daily blow down is essential maintenance for a steam generator It lengthens the l...

Page 8: ...for about 3 secs to turn the unit on C Fill the boiler with water Procedure Complete Daily or Weekly Clean Up 1 IMPORTANT This process is semi automatic and must be followed exactly Frequency of this procedure depends upon frequency of usage Failure to comply with this procedure may void the unit warranty Remove the four funnels from the top of the unit IMPORTANT Use a standard long handle 3 5 scr...

Page 9: ... start the automated cleaning cycle The top gates automatically close The chambers are flushed and rinsed and the bottoms gates are closed When the cleaning cycle is finished approx 30 secs the unit automatically shuts down 6 7 A When finished ensure that all foreign objects are removed from the chambers B Replace the funnels Slide the three dispensers forward to their normal position Ensure that ...